A spline-regularized minimal residual algorithm for iterative attenuation correction in SPECT.
نویسندگان
چکیده
In SPECT, regularization is necessary to avoid divergence of the iterative algorithms used for non uniform attenuation compensation. In this paper, we propose a spline-based regularization method for the minimal residual algorithm. First, the acquisition noise is filtered using a statistical model involving spline smoothing so that the filtered projections belong to a Sobolev space with specific continuity and derivability properties. Then, during the iterative reconstruction procedure, the continuity of the inverse Radon transform between Sobolev spaces is used to design a spline-regularized filtered backprojection method, by which the known regularity properties of the projections determine those of the corresponding reconstructed slices. This ensures that the activity distributions estimated at each iteration present regularity properties, which avoids computational noise amplification, thus stabilizing the iterative process. Analytical and Monte Carlo simulations are used to show that the proposed spline-regularized minimal residual algorithm converges to a satisfactory stable solution in terms of restored activity and homogeneity, using at most 25 iterations, whereas the non regularized version of the algorithm diverges. Choosing the number of iterations is therefore no longer a critical issue for this reconstruction procedure.
منابع مشابه
New approach for attenuation correction in SPECT images, using linear optimization
Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...
متن کاملQuantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملA model based, anatomy dependent method for ultra-fast creation of primary SPECT projections
Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the eff...
متن کاملA new approach to scatter correction in SPECT images based on Klein_Nishina equation
Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 44 10 شماره
صفحات -