Proton Diffusion and T1 Relaxation in Polyacrylamide Gels: A Unified Approach Using Volume Averaging.
نویسندگان
چکیده
The structure of polyacrylamide gels was studied using proton spin-lattice relaxation and PFG diffusion methods. Polyacrylamide gels, with total polymer concentrations ranging from 0.25 to 0.35 g/ml and crosslinker concentrations from 0 to 10% by weight, were studied. The data showed no effect of the crosslinker concentration on the diffusion of water molecules. The Ogston-Morris and Mackie-Meares models fit the general trends observed for water diffusion in gels. The diffusion coefficients from the volume averaging method also fit the data, and this theory was able to account for the effects of water-gel interactions that are not accounted for in the other two theories. The averaging theory also did not require the physically unrealistic assumption, required in the other two theories, that the acrylamide fibers are of similar size to water molecules. Contrary to the diffusion data, T1 relaxation measurements showed a significant effect of crosslinker concentration on the relaxation of water in gels. The model developed using the Bloch equations and the volume averaging method described the effects of water adsorption on the gel medium on both the diffusion coefficients and the relaxation measurements. In the proposed model the gel medium was assumed to consist of three phases (i.e., bulk water, uncrosslinked acrylamide fibers, and a bisacrylamide crosslinker phase). The effects of the crosslinker concentration were accounted for by introducing the proton partition coefficient, Keq, between the bulk water and crosslinker phase. The derived relaxation equations were successful in fitting the experimental data. The partition coefficient, Keq, decreased significantly as the crosslinker concentration increased from 5 to 10% by weight. This trend is consistent with the idea that bisacrylamide tends to form hydrophobic regions with increasing crosslinker concentration. Copyright 1998 Academic Press.
منابع مشابه
Dynamic light scattering from gels in a poor solvent
2014 Photon correlation spectroscopy measurements are reported of the collective motion diffusion coefficient Dc and the longitudinal elastic modulus Egel of polyacrylamide gels in the poor solvent region using a water : methanol (3 : 1 by volume) mixture as solvent. It is shown that the presence of cross-links hinders the movement of polymer self-entanglements, which are characteristic of 03B8...
متن کاملUsing a Temperature Gradient against the Time in Polyacrylamide Gel Electrophoresis May Eliminate the Need for Stacking Gels
Background and Objectives: Making stacking gels for polyacrylamide gels in the laboratory by conventional methods is laborious and time consuming. Considering the role of temperature in polyacrylamide gels with respect to electrical resistance and viscosity, we assumed that decreasing the temperature would cause an increase in electrical resistance and viscosity. Ultimately, a downward tempera...
متن کاملViscoelastic Properties of Polyacrylamide Nanocomposite Hydrogels Prepared in Electrolyte Media: Effect of Gelant Volume
In this work, nanocomposite (NC) hydrogels based on polyacrylamide/chromium triacetate were prepared at different reaction mixture (gelant) volumes and their crosslinking process and viscoelastic behaviors were studied. The X-ray diffraction (XRD) patterns taken from the NC hydrogels containing laponite nanoparticles did not show any distinct characteristic basal reflection for all of the NC hy...
متن کاملProton mobility in molybdenum bronzes
2014 Molybdenum bronzes were prepared by exposing microcrystalline MoO3, covered with small particles of Pt, to gaseous hydrogen. A pulsed proton magnetic resonance study was made of H1.6MoO3 bronzes between 160 and 320 K at 90, 40 and 15 Mhz. The bronzes behave as metallic conductors and, from the point of view of relaxation, are comparable to metallic hydrides. The longitudinal relaxation rat...
متن کاملTemperature mapping with MR imaging of molecular diffusion: application to hyperthermia.
Efficacy and safety considerations for hyperthermia (HT) cancer therapy require accurate temperature measurements throughout the heated volume. Noninvasive thermometry methods have been proposed, including magnetic resonance (MR) imaging based on the temperature dependence of the relaxation time T1. However, the temperature accuracy achieved to date with T1 measurements does not fulfill the HT ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance
دوره 132 2 شماره
صفحات -
تاریخ انتشار 1998