Determination of ochratoxin A in wine and beer by immunoaffinity column cleanup and liquid chromatographic analysis with fluorometric detection: collaborative study.

نویسندگان

  • A Visconti
  • M Pascale
  • G Centonze
چکیده

The accuracy, repeatability, and reproducibility characteristics of a liquid chromatographic method for the determination of ochratoxin A (OTA) in white wine, red wine, and beer were established in a collaborative study involving 18 laboratories in 10 countries. Blind duplicates of blank, spiked, and naturally contaminated materials at levels ranging from < or =0.01 to 3.00 ng/mL were analyzed. Wine and beer samples were diluted with a solution containing polyethylene glycol and sodium hydrogen carbonate, and the diluted samples were filtered and cleaned up on an immunoaffinity column. OTA was eluted with methanol and quantified by reversed-phase liquid chromatography with fluorometric detection. Average recoveries from white wine, red wine, and beer ranged from 88.2 to 105.4% (at spiking levels ranging from 0.1 to 2.0 ng/mL), from 84.3 to 93.1% (at spiking levels ranging from 0.2 to 3.0 ng/mL), and from 87.0 to 95.0% (at spiking levels ranging from 0.2 to 1.5 ng/mL), respectively. Relative standard deviations for within-laboratory repeatability (RSDr) ranged from 6.6 to 10.8% for white wine, from 6.5 to 10.8% for red wine, and from 4.7 to 16.5% for beer. Relative standard deviations for between-laboratories reproducibility (RSDR) ranged from 13.1 to 15.9% for white wine, from 11.9 to 13.6% for red wine, and from 15.2 to 26.1% for beer. HORRAT values were < or =0.4 for the 3 matrixes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of ochratoxin A in grapes, dried vine fruits, and winery byproducts by high-performance liquid chromatography with fluorometric detection (HPLC-FLD) and immunoaffinity cleanup.

A liquid chromatographic method for the determination of ochratoxin A in grapes, dried vine fruits, and winery byproducts was developed. A mixture of either acetonitrile/water or acetonitrile/water/methanol was used as an extraction solvent mixture. After immunoaffinity column cleanup, the final extract was analyzed by high-performance liquid chromatography (HPLC) with a fluorometric detector (...

متن کامل

Liquid chromatographic method with immunoaffinity column cleanup for determination of ochratoxin A in barley: collaborative study.

A collaborative study was conducted to evaluate a liquid chromatographic (LC) method with immunoaffinity column cleanup for determination of ochratoxin A. The method was tested at 3 concentration levels of ochratoxin A in barley, which represent possible future European regulatory limits. The test portion was extracted with acetonitrile-water by blending at high speed. The extract was filtered,...

متن کامل

Validation of an UHPLC-MS/MS method for simultaneous analysis of 11 mycotoxins in wheat flour Using Immunoaffinity column

This study focuses on optimization and validation of an Ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous analysis of 11mycotoxins: Aflatoxin B1, T-2 Toxin, Ochratoxin A, Deoxynivalenol and Zearalenone in wheat matrix. Sample extraction and cleanup procedure is based on a single extraction step using acetonitrile/water/acetic acid mixture...

متن کامل

Immunoaffinity column cleanup with liquid chromatography for determination of aflatoxin M1 in liquid milk: collaborative study.

A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic method for determination of aflatoxin M1 in milk at proposed European regulatory limits. The test portion of liquid milk was centrifuged, filtered, and applied to an immunoaffinity column. The column was washed with water, and aflatoxin was eluted with pure acetonitrile. ...

متن کامل

Combined phenyl silane and immunoaffinity column cleanup with liquid chromatography for determination of ochratoxin A in roasted coffee: collaborative study.

A collaborative study was conducted to evaluate a liquid chromatography (LC) method for ochratoxin A using sequential phenyl silane and immunoaffinity column cleanup. The method was tested at 3 different levels of ochratoxin A in roasted coffee, which spanned the range of possible future European regulatory limits. The test portion was extracted with methanol and sodium bicarbonate by shaking f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of agricultural and food chemistry

دوره 53 14  شماره 

صفحات  -

تاریخ انتشار 2001