Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods.
نویسندگان
چکیده
When the assumption of homoscedasticity is not met for analytical data, a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line is to use weighted least squares linear regression (WLSLR). The purpose of the present paper is to stress the relevance of weighting schemes for linear regression analysis and to show how this approach can be useful in the bioanalytical field. The steps to be taken in the study of the linear calibration approach are described. The application of weighting schemes was shown by using a high-performance liquid chromatography method for the determination of lamotrigine in biological fluids as a practical example. By using the WLSLR, the accuracy of the analytical method was improved at the lower end of the calibration curve. Bioanalytical methods data analysis was improved by using the WLSLR procedure.
منابع مشابه
Calibration Weighting to Compensate for Extreme Values, Non-response and Non-coverage in Labor Force Survey
Frame imperfection, non-response and unequal selection probabilities always affect survey results. In order to compensate for the effects of these problems, Devill and Särndal (1992) introduced a family of estimators called calibration estimators. In these estimators we look for weights that have minimum distance with design weights based on a distance function and satisfy calibration equa...
متن کاملBioanalytical development and validation of liquid chromatographic–tandem mass spectrometric methods for the quantification of total and free cefazolin in human plasma and cord blood
OBJECTIVES Cefazolin is a commonly prescribed β-lactam antibiotic for prophylaxis against skin infections following surgery, including caesarean sections. Assessment of maternal and neonatal exposure is important for correlating drug concentrations to clinical outcomes. Thus, bioanalytical methods for the quantification of both total and free cefazolin in maternal plasma and cord blood can assi...
متن کاملSolution to quality assurance challenge 2.
To validate the HPLC determination of the active pharmaceutical ingredient TAMO in tablets a first calibration set, I, (Table 1, 2nd line) was measured. The experimentally obtained counts are listed in Table 1, 3rd line. In this challenge we tested whether you could detect an outlier in the linear regression function. An outlier shows an unusually high or low residual. The residuals ei are the ...
متن کاملCross-Linguistic Transfer Revisited: The Case of English and Persian
The present study sought to investigate the evidence for cross-linguistic transfer in a partial English immersion and non-immersion educational setting. To this end, a total of 145 first, third and fifth graders in a partial English immersion program and 95 students from the same grade levels in a non-immersion program were chosen. Six different English and Persian tests were administered: the ...
متن کاملAn estimating equations approach to fitting latent exposure models with longitudinal health outcomes
The analysis of data arising from environmental health studies which collect a large number of measures of exposure can benefit from using latent variable models to summarize exposure information. However, difficulties with estimation of model parameters may arise since existing fitting procedures for linear latent variable models require correctly specified residual variance structures for unb...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
دوره 774 2 شماره
صفحات -
تاریخ انتشار 2002