Estimating the 3D skeletons and transverse areas of coronary arteries from biplane angiograms.

نویسندگان

  • K Kitamura
  • J M Tobis
  • J Sklansky
چکیده

A method for estimating the three-dimensional (3D) skeletons and transverse areas of the lumens of coronary arteries from digital X-ray angiograms is described. The method is based on the use of a 3D generalized cylinder (GC) consisting of a series of 3D elliptical disks transverse to and centered on a 3D skeleton (medial axis) of the coronary arteries. The estimates of the transverse areas are based on a nonlinear least-squares-error estimation technique described by D.W. Marquardt (1963). This method exploits densitometric profiles, boundary estimates, and the orientation of the arterial skeleton in 3-space and includes an automatic artery tracking procedure. It applies an adaptive window to the densitometric profile data that are used in the parameter estimation. Preliminary experimental tests of the procedure on angiograms of in vivo human coronaries and on synthetic images yield encouraging results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D Reconstruction of Coronary Artery using Biplane Angiography

In this paper, we present a new method for the 3D reconstruction and visualization of coronary arteries in biplane angiography. The proposed method performs direct reconstruction of 3D coronary artery pathways without computing the 2D or 3D vessel centerlines. A front propagation algorithm is used to reconstruct the coronary artery pathways in 3D space. Starting from one or more 3D points, the ...

متن کامل

Respiratory Motion of the Heart: Implications for Magnetic Resonance Coronary Angiography

Magnetic resonance (MR) coronary imaging is susceptible to artifacts caused by motion of the heart. The purpose of this thesis was to study the respiratory motion of the coronary arteries and to use the results to develop strategies for improved MR imaging. The first section of the thesis describes an MR motion correction technique for objects undergoing a 3D affine transformation. The remainde...

متن کامل

3D Vessel Reconstruction from Biplane Angiograms using Snakes

In this paper, we propose a physics-based model to segment and reconstruct coronary vessels from biplane angiograms. We use the snake technique to model the vessel, the snake deforms in space to adjust its projections to the image data. In this way, segmentation and 3 0 reconstruction are unified into the same procedure assuring that only plausible vessel shapes will be detected. The method is ...

متن کامل

Imaging and Mesh Generation Issues in Patient-specific Simulation Studies of Coronary Hemodynamics

In our simulation studies of coronary hemodynamics, which are described in the companion paper entitled “Image-based Simulation of the threedimensional Coronary Blood Flow” (Quatember et al. 2007), imaging and mesh generation issues are emphasized, particularly the segmentation of the coronary arteries in biplane angiograms, the threedimensional reconstruction of the coronary artery tree and th...

متن کامل

Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: clinical validation.

UNLABELLED Clinical decisions regarding diagnosis and effective treatment of coronary artery disease frequently require integration of information from various imaging modalities, which are acquired, processed, and read at different physical locations and times. We have developed methods to integrate the information in 2 cardiac imaging studies, perfusion SPECT and coronary angiography. Three-d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE transactions on medical imaging

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 1988