Choice of oximeter affects apnea-hypopnea index.
نویسندگان
چکیده
STUDY OBJECTIVES Current Medicare guidelines include an apnea-hypopnea index (AHI) > or = 15 events per hour, in which all hypopneas must be associated with 4% desaturation, to qualify for reimbursement for therapy with continuous positive airway pressure (CPAP). The present data demonstrate the effect of pulse oximeter differences on AHI. DESIGN Prospective study, blinded analysis. SETTING Academic sleep disorder center. PATIENTS One hundred thirteen consecutive patients (84 men and 29 women) undergoing diagnostic sleep studies and being evaluated for CPAP based on the Medicare indications for reimbursement. INTERVENTIONS Patients had two of four commonly used oximeters with signal averaging times of 4 to 6 s placed on different digits of the same hand during nocturnal polysomnography. MEASUREMENTS AND RESULTS Apneas and candidate hypopneas (amplitude reduction, > 30%) were scored from the nasal cannula airflow signal without reference to oximetry. Candidate hypopneas then were reclassified as hypopneas by each oximeter if they were associated with a 4% desaturation. Although the use of three oximeters resulted in a similar AHI (bias, < 1 event per hour), the fourth oximeter showed an overall increase in AHI of 3.7 events per hour. This caused 7 of 113 patients to have an AHI of > or = 15 events per hour (meeting the Medicare criteria for treatment) by one oximeter but not when a different oximeter was used. More importantly, when our analysis was limited to those patients whose number of candidate hypopneas made them susceptible to the threshold value of 15 events per hour, 7 of 35 patients who did not meet the Medicare AHI standard for treatment by one oximeter were reclassified when a different oximeter was used. CONCLUSION In the present study, oximeter choice affected whether the AHI reached the critical cutoff of 15 events per hour, particularly in those with disease severity that was neither very mild nor very severe. As oximetry is not a technique that produces a generic result, there are significant limitations to basing the definition of hypopnea on a fixed percentage of desaturation in determining the eligibility for CPAP therapy.
منابع مشابه
Obstructive sleep apnea-hypopnea results in significant variations in cerebral hemodynamics detected by diffuse optical spectroscopies.
The objective of this study was to adapt a novel near-infrared diffuse correlation spectroscopy (DCS) flow-oximeter for simultaneous and continuous monitoring of relative changes in cerebral blood flow (rCBF) and cerebral oxygenation (i.e. oxygenated/deoxygenated/total hemoglobin concentration: Δ[HbO2]/Δ[Hb]/ΔTHC) during overnight nocturnal polysomnography (NPSG) diagnostic test for obstructive...
متن کاملDetermination of The Relationship Between Severity of Obstructive Sleep Apnea And Chronic Obstructive Pulmonary Disease
Introduction: Chronic obstructive pulmonary disease (COPD) patients are at increased risk of sleep-disorders. The concomitant occurrence of COPD and obstructive sleep apnea hypopnea syndrome (OSAHS) is named overlap syndrome. This study aimed to evaluate the severity of OSAHS in overlap syndrome patients.Materials & Methods: This cross-sectional study was conducted on adult patients with forced...
متن کاملThe Evaluation of Diastolic Hypertention in Sleep Overlap Syndrome
Introduction:The overlap syndrome, consisting ofobstructive sleep apnea hypopnea syndrome (OSAHS) and chronic obstructvie pulmonary disease (COPD) is a major problem in COPD patients. OSHAS corresponds to the likelihood of systemic hypertension.The present study was aimed to evaluate the association between apnea-hypopnea index and diastolic blood presssure (DBP) in overlap patients. Materials...
متن کاملAutomated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea.
BACKGROUND The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. The diagnostic performance of an automated analysis algorithm based on falls and recov...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 127 1 شماره
صفحات -
تاریخ انتشار 2005