Ovarian masses: MR imaging with T1-weighted 3-dimensional gradient-echo IDEAL water-fat separation sequence at 3T.
نویسندگان
چکیده
PURPOSE We retrospectively compared the efficacy of 3-dimensional (3D) gradient-echo magnetic resonance T(1)-weighted sequence using the iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) technique with the efficacy of conventional 3D gradient-echo sequences for diagnosing ovarian masses at 3T. MATERIALS AND METHODS In images of 32 women (mean age, 45.3 years) with ovarian masses who underwent T(1)-weighted imaging with both IDEAL and conventional techniques, we quantitatively analyzed signal-to-noise ratio (SNR) and contrast between gluteal muscle and T(1)-weighted high-signal materials within lesions and assessed image quality. Two radiologists independently evaluated fat detection. RESULTS Mean SNR of subcutaneous fat did not differ significantly between IDEAL and conventional techniques for both fat-suppressed (P=.32) and non-fat-suppressed (P=.85) images. Mean absolute contrast between gluteal muscle and T(1)-weighted high signal materials within teratomas (n=15) was significantly higher with IDEAL on fat-suppressed images (P=.002) and lower with IDEAL on non-fat-suppressed images (P=.010). Fat suppression was significantly superior with IDEAL (P<.0001). Readers' assessments of fat detection did not differ between IDEAL and conventional sequences. CONCLUSION The quality of T(1)-weighted fat-suppressed images of ovarian masses was better with 3D gradient-echo IDEAL than conventional 3D gradient-echo sequences.
منابع مشابه
Improved image contrast and scan efficiency for fat suppressed T1-weighted imaging at 3T with a spin echo two-point Dixon technique
Introduction: Fat suppressed T1-weighted imaging is often an essential component of a clinical MRI exam. Compared to several relatively newer pulse sequences (e.g., spoiled gradient echo, T1FLAIR, FSE), the conventional spin echo (SE) sequence still produces the best T1-contrast and is preferred by many radiologists for certain applications (such as for imaging of head & neck). However, inclusi...
متن کاملStaging urinary bladder cancer: value of T1-weighted three-dimensional magnetization prepared-rapid gradient-echo and two-dimensional spin-echo sequences.
OBJECTIVE The purpose of this study was to evaluate a magnetization prepared-rapid gradient-echo (MP-RAGE) sequence as a three-dimensional T1-weighted MR imaging technique for staging urinary bladder cancer and to compare this technique with a commonly used two-dimensional T1-weighted spin-echo sequence technique. SUBJECTS AND METHODS For 28 consecutive patients with urinary bladder cancer, M...
متن کاملAlternative T1-weighted In-phase/Out-of-phase Imaging For Body MRI at 3T
A. T. Vu, V. M. Mai, P. V. Prasad, R. R. Edelman Evanston Northwestern Healthcare, Feinberg School of Medicine, Northwestern Univeristy, Evanston, IL, United States Synopsis An alternative T1-weighted fat/water in-phase/out-of-phase gradient echo imaging pulse sequence is proposed for routine body MRI at 3T. The pulse sequence provides T1 weighting using single shot inversion recovery preparati...
متن کاملThe effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence
Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...
متن کاملT1-weighted three-dimensional magnetization transfer MR of the brain: improved lesion contrast enhancement.
PURPOSE We developed and evaluated clinically T1-weighted three-dimensional gradient-echo magnetization transfer (MT) sequences for contrast-enhanced MR imaging of the brain. METHODS A short-repetition-time, radio frequency-spoiled, 3-D sequence was developed with a 10-millisecond MT pulse at high MT power and narrow MT pulse-frequency offset, and the enhancing lesion-to-normal white matter b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine
دوره 11 2 شماره
صفحات -
تاریخ انتشار 2012