Development and validation of an automated latex-enhanced immunoassay for prealbumin.

نویسندگان

  • P Holownia
  • D J Newman
  • H Thakkar
  • W D Bedzyk
  • H Crane
  • Y Olabiran
  • C L Davey
  • C P Price
چکیده

The measurement of circulating prealbumin has been shown to be clinically useful in the assessment of nutritional status, both as an initial screen and in the monitoring of nutritional recovery. We describe a fully automated, noncompetitive, homogeneous, light-scattering immunoassay that has been developed for this analyte on a Dimension (Dade) analyzer. A sheep anti-prealbumin IgG fraction was covalently coupled to 40-nm chloromethyl styrene particles and, after the addition of sample, polyethylene glycol-assisted immunoagglutination was monitored by turbidimetry. The prealbumin working assay range was 8-550 mg/L at a sample volume of 2 microL and a reaction time of 6.5 min. When data were analyzed using ANOVA, total and within-run assay imprecision values (CVs) were 1-5%, and calibration and reagent stabilities were in excess of 40 days. Mean analytical recoveries were 102% +/- 4% (SD), and there was no lack of parallelism. Hemolysis, lipemia, and bilirubin did not interfere. Both plasma anticoagulated with heparin or EDTA and serum from plain or serum-separation tubes were acceptable as sample matrices. Comparison with the Beckman Array method gave a Passing and Bablok regression of: Dimension analyzer = 1.01Beckman + 7.1 (n = 103), using a common calibrator. We conclude that the prealbumin method is appropriate for clinical use according to the analytical criteria used in this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Latex Agglutination Method for Diagnosis of Rotavirus Infections

Background: Rotavirus is a major cause of morbidity and mortality among children with gastroenteritis. Since the discovery of rotaviruses, several techniques have been used for their laboratory diagnosis; those included Electron Microscopy (EM) and enzyme immunoassay. These methods, however, are expensive and not readily available everywhere. We have developed a technique which can be used for ...

متن کامل

Development and multicenter evaluation of the N latex CDT direct immunonephelometric assay for serum carbohydrate-deficient transferrin.

BACKGROUND Carbohydrate-deficient transferrin (CDT) is a promising biomarker of alcohol abuse. We describe the development and multicenter evaluation of N Latex CDT (Dade Behring), an automated, particle-enhanced, homogeneous immunonephelometric assay for directly determining CDT. METHODS N Latex CDT uses a monoclonal antibody that recognizes the structure of transferrin glycoforms lacking 1 ...

متن کامل

Serum cystatin C measured by automated immunoassay: a more sensitive marker of changes in GFR than serum creatinine.

Serum cystatin C has been suggested as a new marker of GFR. For the introduction of this marker into clinical use a rapid and automated method is required. We have developed and validated an assay for serum cystatin C using latex particle-enhanced immunoturbidimetry. Intra- and inter-assay precision were < 3% and < 5% across the assay range. Analytical recovery was 93 +/- 3.8% and no lack of pa...

متن کامل

A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection

Golgi protein 73 (GP73) is a novel and potential marker for diagnosing hepatocellular carcinoma (HCC) that has been found to be abnormally elevated in liver disease. A latex particle-enhanced turbidimetric immunoassay (LTIA) was recently introduced and licensed for application in a variety of automated clinical chemistry analyzers. However, no studies have reported sufficient data on analytical...

متن کامل

Adaptation of latex-enhanced assay for percent glycohemoglobin to a Dade Dimension analyzer.

At present no method for glycohemoglobin (%HbA1c) is automated on a main-line analyzer to allow joint measurement with other indicators of diabetic control such as glucose and cholesterol. We describe an adaptation of a latex-enhanced competitive immunoassay for quantifying %HbA1c to the Dade International Dimension analyzer. After a manual hemolysis step, HbA1c and total hemoglobin (Hb) are de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 6 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1998