[Correlation and concordance between echocardiographic measurements obtained during echocardiography and digitized image measurements--transversal study].
نویسندگان
چکیده
OBJECTIVE To evaluate the correlation and concordance between the measurements of echocardiographic analysis of cardiac dimensions obtained through the Echo off-line applicative (software for obtaining digitized image measurements in a dedicated workstation) available to public domain, and those obtained through the conventional method. METHOD Transversal contemporary study, of 56 randomized patients whose images were obtained during examinations. The measurements of the M mode and 2D, were done in the ventricles, left atrium, and aorta by the Echo off-line program. These measurements were compared to those obtained by another professional, through Pearson's correlation test (r), alpha = 0.05 and by concordance analysis (Bland and Altman). RESULT The measurements carried out by the Echo off-line system showed r that varied from 0.85 to 0.98. The analysis of concordance showed that for most measurements, the mean difference between the methods was approximately zero. The variation of absolute values did not show, in average, a clinical significance. The Echo off-line applicative allows a reduction of approximately 30% in the time spent to obtain the measurements. CONCLUSION This study demonstrated the accuracy of the Echo off-line program to measure cardiac dimensions in a dedicated workstation, showing that it can be routinely used in echocardiography labs.
منابع مشابه
Measurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images
Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...
متن کاملHigh concordance of invasive and echocardiographic mean pressure gradients in patients with a mechanical aortic valve prosthesis.
BACKGROUND AND AIM OF THE STUDY Conflicting data exist regarding the accuracy of echocardiographic Doppler gradients compared to invasive pressure gradients in the hemodynamic assessment of patients with prosthetic aortic valves. The study aim was to determine the correlation between these measurements for mechanical single- and double-leaflet aortic valve prostheses in vivo. METHODS Forty-fo...
متن کاملComparison of m-mode echocardiographic left ventricular mass measured using digital and strip chart readings: The Atherosclerosis Risk in Communities (ARIC) study
BACKGROUND Epidemiological and clinical studies frequently use echocardiography to measure LV wall thicknesses and chamber dimension for estimating quantitative measures of LV mass. While echocardiographic M-mode LV images have traditionally been measured using hand-held calipers and strip-chart paper tracings, digitized M-mode LV image measurements made directly on the computer screen using el...
متن کاملComparative study of cardiac anatomic measurements obtained by echocardiography and dual-source computed tomography.
The aim of this study was to verify the accuracy of echocardiography by dual-source computed tomography (DSCT). Seven normal beagles underwent DSCT and echocardiography. Echocardiographic measurements were obtained according to the American Society of Echocardiography guidelines. The DSCT images were reconstructed onto the same echocardiographic image plane by using a reconstruction program, an...
متن کاملStudy of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat
Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...