Development and Benchmarking of Codes for Simulation of Beam-beam Effects at the Lhc

نویسنده

  • F. Schmidt
چکیده

The code is described in more detail in the Proceedings of PAC05 [1]. Below a brief summary of the code features is given. Lifetrac is a weak-strong beam-beam code that was originally created for simulating equilibrium distributions in electron-positron colliders (circa 1995). Eventually, the author added the functionality to simulate non-equilibrium distributions (2003-2004), making it a conventional macro particle tracking code. Lifetrac tracks a bunch of particles through the machine lattice and beam-beam interactions. The major design principles are the following

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...

متن کامل

Effect of Dental Filling Materials on Electron Beam Radiotherapy Dose Distribution in Head Region: a Monte Carlo Study by FLUKA and MCNPX Codes

Introduction: Radiation therapy is regarded as the mainstay treatment for head or neck cancer patients. In this method, the backscattered radiation of dental composites can damage the surrounding tissue. Material and Methods: The current study compared the effects of electron beam radiation on healthy teeth with the tooth filled with material...

متن کامل

Evaluating the Effects of Field Size on Beam Homogeneity Coefficient in the Superficial Radiotherapy Machine Using Empirical Method and Simulation

Introduction Superficial X-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (Up to 300 kVp). Quality of the X-ray beam that can be expressed by Half-Value Layer (HVL), are important indices for this type of treatment effective energy of photon and Homogeneity Coefficient (HC). Materials and Methods The HC of the s...

متن کامل

Monte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator

Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...

متن کامل

طراحی و شبیه‌سازی ستون شتابدهنده دوترونی الکترواستاتیکی 2MV

In this paper design and simulation of an optimized accelerator tube is presented for the production of light charged particles up to energy of 2 MeV. Geometry of the accelerator tube electrodes was simulated based on the Van De Graaff accelerator tubes of Atomic Energy Organization by SIMION 7.0, Virtual Device and SIMION Toolkit codes. In accelerator tube, the extracted ion beam from the ion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -