Optimal phase difference reconstruction: comparison of two methods.

نویسندگان

  • Kun Lu
  • Thomas T Liu
  • Mark Bydder
چکیده

The present study compares the performance of the weighted mean (WM) and sensitivity encoding (SENSE) methods for reconstructing phase difference images over a large range of signal-to-noise ratio (SNR). It is found that the WM algorithm is suboptimal, compared to the SENSE method at low SNR. Numerical simulations, phantom and in vivo results are presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software

Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...

متن کامل

Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators

Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

Target detection The Simulation Analysis of the Effect of Imaging Side‌lap/Overlap on the Quality of 3D Reconstruction in UAV Photogrammetry and Determination of their Optimal Values

The selection of effective and optimal sidelap/overlap of images according to the quality, speed, cost and purpose of each UAV photogrammetric project is considered as an important parameter. Since two decades ago, several researches have been carried out based on a trial and error strategy for this purpose, in which different drones and cameras have been utilized for imaging with different sid...

متن کامل

Investigation and comparison of calcium aluminate phases obtained by three methods of sol-gel (with EDTA), sol-gel (without EDTA) and solid-phase synthesis

In this study, we investigate calcium aluminate phases that were prepared by three different solid phase synthesis methods and a sol-gel method (with and without EDTA). The purpose of this study is to compare these three methods in terms of achieving higher purity, optimal phase and complexity in the production of the final product. Comparing the results, we found that the sol-gel method is mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2008