Spirometer Replacement and Serial Lung Function Measurements in Population Studies: Results From the SAPALDIA Study.

نویسندگان

  • Pierre-Olivier Bridevaux
  • Elise Dupuis-Lozeron
  • Christian Schindler
  • Dirk Keidel
  • Margaret W Gerbase
  • Nicole M Probst-Hensch
  • Robert Bettschart
  • Luc Burdet
  • Marco Pons
  • Thomas Rothe
  • Alexander Turk
  • Daiana Stolz
  • Jean-Marie Tschopp
  • Nino Kuenzli
  • Thierry Rochat
چکیده

The Swiss Cohort Study on Air Pollution and Lung and Heart Disease in Adults (SAPALDIA), a population cohort study, used heated-wire spirometers in 1991 and 2002 and then ultrasonic spirometers in 2010 revealing measurement bias in healthy never smokers. To provide a practical method to control for measurement bias given the replacement of spirometer in long-term population studies, we built spirometer-specific reference equations from healthy never smokers participating in 1991, 2002, and 2010 to derive individualized corrections terms. We compared yearly lung function decline without corrections terms with fixed terms that were obtained from a quasi-experimental study and individualized terms. Compared with baseline reference equations, spirometer-specific reference equations predicted lower lung function. The mean measurement bias increased with age and height. The decline in forced expiratory volume in 1 second during the reference period of 1991-2002 was 31.5 (standard deviation (SD), 28.7) mL/year while, after spirometer replacement, uncorrected, corrected by fixed term, and individualized term, the declines were 47.0 (SD, 30.1), 40.4 (SD, 30.1), and 30.4 (SD, 29.9) mL/year, respectively. In healthy never smokers, ultrasonic spirometers record lower lung function values than heated-wire spirometers. This measurement bias is sizeable enough to be relevant for researchers and clinicians. Future reference equations should account for not only anthropometric variables but also spirometer type. We provide a novel method to address spirometer replacement in cohort studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of equipment and technique on peak flow measurements

BACKGROUND Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF) results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. METHODS We studied 36 subjects (PEF range 80-570 l/min). All patients reco...

متن کامل

The SAPALDIA cohort: design and results in the field of respiratory and cardio-vascular diseases

The SAPALDIA (Swiss Study on Air Pollution and Lung Disease in Adults) cohort involving eight geographical areas of Switzerland was initiated in 1991 for studying the effects of air pollution on the respiratory and cardiovascular health in adults. The study was initiated with a cross-sectional interview of 9651 subjects aged 18 to 60 years and more than 90% of them underwent lung function and a...

متن کامل

بررسی تغییرات حجم‌های ریه پس از اصلاح زاویه اسکولیوز

    Background and Aim: The present studies on kyphoscoliosis operation demonstrate different results on lung volume changes. Some observations show increased, some show decreased and other studies show no changes in the dynamic respiratory flows.In this study we evaluated lung volumes before and after surgery. We also evaluated the correlation of repiratory lung volume changes with mean of Cob...

متن کامل

Lung function in our aging population

UNLABELLED AIMS OF INVESTIGATION: The chronological age of the Caucasian population and their anthropometrical data have significantly changed within the last five decades. Therefore the question arises whether or not the commonly used reference values of the European Community (ECCS) for lung function may still be accepted today. Since these values were obtained in the 1960s from subjects in a...

متن کامل

Calibrating the calibrators.

Serial measures of lung function are essential for the long term monitoring of chronic diseases such as chronic obstructive pulmonary disease (COPD) and pulmonary fibrosis where the main aim is to limit disease progression. Measures of forced expiratory volume in one second (FEVI) and forced vital capacity (FVC) are generally the most reproducible and therefore suitable for long term disease mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of epidemiology

دوره 181 10  شماره 

صفحات  -

تاریخ انتشار 2015