Endovascular stent-graft procedures in aorto-iliac pathologies: a single center experience

نویسندگان

  • A Kucuker
  • M Hidiroglu
  • M Canyigit
  • L Cetin
  • F Saglam
  • E Sener
چکیده

Methods 117 endovascular stent-graft procedures in 113 patients for thoracic, abdominal and iliac pathologies was performed at our institute between January 2009-April 2013. 94(83.1%) patients were male. Indications for endovascular interventions were as follows; 58 for abdominal aortic aneursym, 14 for descending aortic aneursym, 4 for both descending and abdominal aortic aneursyms, 2 for thoraco-abdominal aneurysm including visceral arteries, 22 for aortic dissection, 2 for penetrating ulcer, 6 for traumatic aortic rupture, 1 for intramural hematoma, 1 for bronchial artery aneurysm and 3 for common iliac artery aneursym. Chimney and periscope techniques were used in 2 patients and iliacbranched endograft was placed in 2 patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using a Surgeon-modified Iliac Branch Device to Preserve the Internal Iliac Artery during Endovascular Aneurysm Repair: Single-center Experiences and Early Results

BACKGROUND To evaluate the feasibility of a new surgeon-modified iliac branch device (IBD) technique to maintain pelvic perfusion in the management of common iliac artery (CIA) aneurysm during endovascular aneurysm repair (EVAR). METHODS From January 2011 to December 2013, a new surgeon-modified IBD technique was performed in department of vascular surgery of Peking Union Medical College Hosp...

متن کامل

Delayed Type III Endoleak Caused by Fabric Erosion after Endovascular Repair of an Abdominal Aortic Aneurysm

A 74-year-old patient presented with recurrent aneurysms in the infrarenal abdominal aorta and right common iliac artery 6 years after endovascular aortic repair using endografts in the same location. The patient underwent an aorto-bi-iliac replacement with removal of the stent graft. Two holes measuring 2 mm each were found in the removed graft, and they appeared to have been caused by wear fr...

متن کامل

Aorto-Uni-Iliac Stent Grafting and Femoro-Femoral Bypass in a Patient with a Failed and Catastrophic Endovascular Aortic Aneurysm Repair

A 78-year-old man presented at Eulji University Hospital due to an abdominal aortic aneurysm with maximum diameter of 52 mm, which had been increased from 45 mm over 6 months. He underwent embolization of the left internal iliac artery with vascular plug, prior to endovascular abdominal aortic repair with a bifurcated stent graft system. Unfortunately, the inserted vascular plug was maldeployed...

متن کامل

Incidence and treatment of intraoperative technical problems during endovascular repair of complex abdominal aortic aneurysms.

PURPOSE The purpose of this study was to assess the incidence and management of intraoperative technical problems during endovascular repair (EVR) of complex abdominal aortic aneurysms (AAA). METHODS From February 1995 to March 1999, 204 EVRs of nonruptured AAA were performed at our institution. One hundred seventy-six patients had an in-house custom-made graft; 172 were aorto-uni-iliac graft...

متن کامل

Endovascular stent graft repair of aorto-iliac pseudoaneurysms - Hospital Kuala Lumpur experience.

BACKGROUND This is a single institutional review of aortoiliac pseudoaneurysm of various aetiologies managed with endovascular stent graft repair. METHODS From 2009 to 2014, 16 patients had endovascular stent graft inserted for pseudoaneurysm of the thoracic aorta, abdominal aorta and iliac arteries in Hospital Kuala Lumpur. Co-morbidity, causative agents, in-hospital mortality, complications...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013