Automated enzyme assays.

نویسندگان

  • J A Lott
  • D A Nealon
چکیده

1 . Introduction 2. What is Automation? 3. Solution-Based, Absorption Spectrophotometric Methods 3.1. Specimen Identification 3.2. Specimen Preparation 3.3. Specimen Integrity 3.4. Pipeting Specimens 3.5. Temperature Control 3.6. Absorbance Accuracy 3.7. Wavelength Accuracy 3.8. Time Control 3.9. Cuvet Control 3.10. Control of Interferences 3.10.1. Keto Acids 3.10.2. Ammonium Ions 3.10.3. Glycerol 3.10.4. Oxidized Enzymes 3.10.5. Amino-Alcohol Buffers 3.1 1 , Photometric Accuracy 3.12. 3.12.1. Lag Phase 3.12.2. Extracting Enzyme Activities from Spectrophotometric Data

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Alkaline Phosphatase Lacking Wheat Germ Agglutinin Binding Sites Useful Enzyme for Lectin Assays with Comparable Activity to the Calf Enzyme

Despite the availability of various alkaline phosphatase (ALP) isoenzymes, the calf enzyme is being used in current enzyme assays as the detector enzyme. The glycosylation pattern of this enzyme makes it a suitable ligand for binding to wheat germ agglutinin lectin (WGA). As a result of this property, the enzyme can not be used as a conjugate with this lectin, and the calf enzyme conjugates can...

متن کامل

Optimising automation of a manual enzyme-linked immunosorbent assay

OBJECTIVE Enzyme-linked immunosorbent assays (ELISAs) are widely used to quantify immunoglobulin levels induced by infection or vaccination. Compared to conventional manual assays, automated ELISA systems offer more accurate and reproducible results, faster turnaround times and cost effectiveness due to the use of multianalyte reagents. DESIGN The VaccZyme™ Human Anti-Haemophilus influenzae t...

متن کامل

Automated Assay of Glycosidasesl

Automated methodology for monitoring the presence of one or more glycosidases in biological extracts has been described (l-7). These procedures require use of large amounts of synthetic glycoside(s) (l-4,6,7), compound automated systems (5), or extensive mechanical and/or electrical alterations of existing apparatus (8). The present paper describes a simple modification of the Technicon Basic A...

متن کامل

Stepping up ELISpot: Multi-Level Analysis in FluoroSpot Assays

ELISpot is one of the most commonly used immune monitoring assays, which allows the functional assessment of the immune system at the single cell level. With its outstanding sensitivity and ease of performance, the assay has recently advanced from the mere single function cell analysis to multifunctional analysis by implementing detection reagents that are labeled with fluorophores (FluoroSpot)...

متن کامل

Automated computer analysis for enzyme-multiplied immunological techniques.

The dose/response curve in enzyme-multiplied immunoassays (EMIT) and related techniques may be described by the same "four-parameter logistic function" as has proven useful in radioimmunoassays, immunoradiometric assays (IRMA), and two-site immunoradiometric ("sandwhich") assays. This function provides an empirical description of the dose/response curve by use of an objective least-squares regr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Methods of biochemical analysis

دوره 37  شماره 

صفحات  -

تاریخ انتشار 1994