Measurement of mean arterial pressure: comparison of the Vasotrac monitor with the finger differential oscillometric device.
نویسندگان
چکیده
The Vasotrac monitor provides non-invasive near-continuous blood pressure monitoring and is designed to be an alternative to direct intra-arterial blood pressure (BP) measurement. As compared to radial artery invasive BP and upper arm non-invasive BP, Vasotrac readings have been found to have a good agreement with them. However, discrepancies have been reported when rapid changes in BP exist. In the present study we compared BP measured by the Vasotrac monitor on the radial artery with that recorded on the finger arteries by the differential oscillometric device allowing measurement on the beat-to-beat basis. Comparisons were performed on the mean arterial pressure (MAP) level. Special attention was paid to the signal conditioning before comparison of pressures of different temporal resolution. Altogether 383 paired MAP measurements were made in 14 healthy subjects. Based on all 383 paired measurements, the MAP values measured at the radial artery at rest were 4.8+/-6.0 mm Hg higher than those measured on fingers. The observed difference between the Vasotrac and differential oscillometric device can be explained by different measurement sites. This result is consistent with previous investigations, and the Vasotrac monitor can be considered to adequately track relatively rapid MAP changes on the radial artery. Attention should be paid to a proper signal conditioning before comparison of results obtained by different devices.
منابع مشابه
A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery.
BACKGROUND In morbidly obese patients, oscillometric blood pressure measurements with an upper-arm cuff are often difficult to perform. The alternative method, invasive blood pressure monitoring, can be difficult to place and is associated with risks. A wrist-mounted blood pressure-monitoring device, the Vasotrac, provides accurate blood pressure measurements in lean patients. Even in the obese...
متن کاملA comparison of radial artery blood pressure determination between the Vasotrac device and invasive arterial blood pressure monitoring in adolescents undergoing scoliosis surgery.
UNLABELLED The Vasotrac device (Medwave, Arden Hills, MN) allows noninvasive measurement of arterial blood pressure (BP) and arterial waveform. We have previously demonstrated agreement between the Vasotrac and continuous intraarterial BP monitoring in children with a stable circulation after cardiac surgery in the cardiac intensive care unit. To assess this monitor during different physiologic...
متن کاملProspective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits
BACKGROUND Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the ...
متن کاملA new noninvasive method to measure blood pressure: results of a multicenter trial.
BACKGROUND Blood pressure (BP) monitoring with arterial waveform display requires an arterial cannula. We evaluated a new noninvasive device, Vasotrac (Medwave, Arden Hills, MN) that provides BP measurements approximately every 12-15 beats and displays pulse rate and a calibrated arterial waveform for each BP measurement. METHODS Surgical and critically ill patients (n = 80) served as subject...
متن کاملArterial stiffness as underlying mechanism of disagreement between an oscillometric blood pressure monitor and a sphygmomanometer.
Oscillometric blood pressure devices tend to overestimate systolic blood pressure and underestimate diastolic blood pressure compared with sphygmomanometers. Recent studies indicate that discrepancies in performance between these devices may differ between healthy and diabetic subjects. Arterial stiffness in diabetics could be the underlying factor explaining these differences. We studied diffe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological research
دوره 59 5 شماره
صفحات -
تاریخ انتشار 2010