A novel device for collecting and dispensing fingerstick blood for point of care testing

نویسندگان

  • Alexis F Sauer-Budge
  • Samuel J Brookfield
  • Ronald Janzen
  • Sarah McGray
  • Anna Boardman
  • Holger Wirz
  • Nira R Pollock
چکیده

The increased world-wide availability of point-of-care (POC) tests utilizing fingerstick blood has led to testing scenarios in which multiple separate fingersticks are performed during a single patient encounter, generating cumulative discomfort and reducing testing efficiency. We have developed a device capable of a) collection of up to 100 μL of fingerstick blood from a single fingerstick by capillary action, and b) dispensing this blood in variable increments set by the user. We tested the prototype device both in a controlled laboratory setting and in a fingerstick study involving naive device users, and found it to have accuracy and precision similar to a conventional pipettor. The users also found the device to be easy to use, and recommended minor ergonomic improvements. Our device would allow performance of multiple POC tests from a single fingerstick blood sample, thus providing a novel functionality that may be of use in many testing settings worldwide.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation of fingerstick blood collection for point-of-care HIV-1 viral load monitoring in South Africa.

BACKGROUND Viral load (VL) quantification is an important tool in determining newly developed drug resistance or problems with adherence to antiretroviral therapy (ART) in HIV-positive patients. VL monitoring is becoming the standard of care in many resource-limited settings. Testing in resource-limited settings may require sampling by fingerstick because of general shortages of skilled phlebot...

متن کامل

Comparison of point-of-care and laboratory glucose analysis in critically ill patients.

BACKGROUND Blood for point-of-care analysis of glucose levels is often obtained from different sources (fingerstick, arterial or central venous catheter). OBJECTIVES To examine agreement between point-of-care and laboratory glucose values and to determine effects of hematocrit, serum carbon dioxide, and mean arterial pressure on the accuracy of point-of-care values. METHODS Point-of-care va...

متن کامل

A paper-based multiplexed transaminase test for low-cost, point-of-care liver function testing.

In developed nations, monitoring for drug-induced liver injury through serial measurements of serum transaminases [aspartate aminotransferase (AST) and alanine aminotransferase (ALT)] in at-risk individuals is the standard of care. Despite the need, monitoring for drug-related hepatotoxicity in resource-limited settings is often limited by expense and logistics, even for patients at highest ris...

متن کامل

Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study

BACKGROUND Cryptococcus neoformans is the most common cause of adult meningitis in sub-Saharan Africa. The cryptococcal antigen (CRAG) lateral flow assay (LFA) has simplified diagnosis as a point-of-care test approved for serum or cerebrospinal fluid (CSF). We evaluated the accuracy of the CRAG LFA using fingerstick whole blood compared with serum/plasma and CSF for diagnosing meningitis. MET...

متن کامل

Design and Implementation of an Automated Dispensing Device for Reducing Methadone Therapy Misuse

Introduction: A variety of (deliberate or inaccurate) errors in drug rehabilitation clinics may occur  due to use of addictive drugs. Automated drug distribution systems play a significant role in reducing drug medication errors. Method: Firstly, according to the addiction rehabilitation centers requests, the design and construction of the device was performed. The prototype systems were examin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017