Transesophageal echocardiographic evaluation during aortic valve repair surgery.
نویسندگان
چکیده
For patients with aortic valve (AV) disease, the classic treatment has been AV replacement and this remains true for aortic stenosis. In contrast, repair of isolated aortic insufficiency (AI), with or without aortic root pathology, is emerging as a feasible and attractive option to replacement. The AV is one of the elements of the aortic root. As such, AI can develop if one or more elements of the aortic root are diseased. Intraoperative transesophageal echocardiographic evaluation permits analysis of the mechanisms of aortic regurgitation as well as differentiation between repairable and unrepairable AV pathology. Immediate postrepair transesophageal echocardiography provides important information about the quality and durability of repair and identifies variables associated with recurrent AI.
منابع مشابه
Live/real time three-dimensional transesophageal echocardiographic evaluation of mitral and aortic valve prosthetic paravalvular regurgitation.
Thirteen patients already scheduled for surgery for repair of prosthetic paravalvular regurgitation underwent intraoperative real time two-dimensional transesophageal echocardiography (2D TEE) and live/real time three-dimensional transesophageal echocardiography (3D TEE). In all patients, 3D TEE was able to provide more information regarding the location and size of the paravalvular defect as c...
متن کاملIntraoperative echocardiographic delineation of the high take-off coronary ostia during an extensive surgical repair of the bicuspid aortic valve and dilated sinotubular junction: a case report
BACKGROUND This study reports the efficacy of intraoperative transesophageal echocardiography (TEE) for evaluation of high take-off coronary ostia and proximal coronary arterial flows as an alternative to preoperative coronary angiography. CASE PRESENTATION In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junctio...
متن کاملQuadricuspid Aortic Valve Diagnosed by Transesophageal Echocardiography: A Case Report
Quadricuspid aortic valve (QAV) is an uncommon congenital anomaly which was an incidental finding during surgery or autopsy in the past. We present the case of a 44-year-old woman with moderately severe aortic regurgitation due to unequal cusp size QAV diagnosed via transesophageal echocardiography. Due to echocardiographic imaging improvement, the diagnosis of QAV is now easier and earlier tha...
متن کاملTransesophageal echocardiographic description of the mechanisms of aortic regurgitation in acute type A aortic dissection: implications for aortic valve repair.
OBJECTIVES The purpose of this study was to use transesophageal echocardiography (TEE) to define the mechanisms of aortic regurgitation (AR) in acute type A aortic dissection so as to assist the surgeon in identifying patients with mechanisms of AR suitable for valve preservation. BACKGROUND Significant AR frequently complicates acute type A aortic dissection necessitating either aortic valve...
متن کاملAortic valve leaflet perforation after mitral valve repair.
A 32-year-old patient with symptomatic severe aortic regurge, 6 weeks after mitral valve repair, was admitted for aortic valve surgery. No preoperative clinical data consistent with infective endocarditis could be detected. Preoperative transthoracic echocardiography showed aortic leaflet perforation affecting non coronary cusp. During operation, leaflet perforation was detected and closed comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesia and analgesia
دوره 111 1 شماره
صفحات -
تاریخ انتشار 2010