Effect of Detergent on Kinetic Jaff#{233}-Method Assay of Creatinine
نویسندگان
چکیده
A similar expression would result if different dilution steps were used for each ampoule or different coefficients of variation were used for different dilution steps or solutions. The sum above (S2) would include terms (1 d)2(Cv2 + CA2) with appropriate values of d, Cv and CA for each step. If R is the estimate of the relative potency computed for an assay, then for known relative potency, r, and usual methods of estimation, log R is normally distributed with respective mean and variance of
منابع مشابه
Automated reaction-rate method for determination of serum creatinine with the CentrifiChem.
An automated kinetic method to determine creatinine in serum with the Jaff#{233} reaction is described. The method does not require deproteinization or adsorption of creatinine on Fuller’s earth or ion.exchange resin. A maximum of 29 serum samples, standards, and control sera can be assayed in less than 1.5 mm. Interferences by most of the known Jaff#{233}-positive serum constituents were studi...
متن کاملBilirubln interference with the KinetIc Jaff # { 233 } Method for Serum Creatinine
392 CLINICAL CHEMISTRY, Vol. 24, No. 2, 1978 In the case of copper and zinc, the authors are to be congratulated on the excellent reproducibility of the techniques used. The fact that different wash procedures gave somewhat different results need not be surprising if one assumes that the efficiency in nemoving contaminating metal varied with the procedure. A point of criticism is their use of a...
متن کاملDevelopment and validation of a liquid-chromatographic procedure for serum creatinine.
We evaluated and compared three analytical procedures for measuring creatinine by testing pooled sera and sera from individual human subjects. In two of the methods, an enzymic and a conventional colorimetric procedure, creatinine was separated from serum proteins with tungstic acid and detected at 520 nm after reaction with alkaline picrate (Jaff#{233} reagent). The amount of enzymaticaIly act...
متن کاملCombinedEnzymic - Jaff # { 233 } Methodfor Determinationof Creatininein Serum
Concentrations of creatinine, as determined in serum by a method involving the combined use of creatinine amidohydrolase (EC 3.5.2.10) and alkaline sodium picrate were found to be factitiously low, owing to a reversal of the enzyme reaction. This effect could be eliminated by converting creatine, the product of the enzymic reaction, to creatine phosphate. The combined enzymic-Jaff#{233} method ...
متن کاملNew kinetic method for creatinine measurement now automated in the Cobas Fara centrifugal analyzer.
A new kinetic method to determine creatimne in serum by using an alkaline 3,5-dinitrobenzoate solution was recently reported (1). Interference from pseudo-creatinine chromogens, bilirubin, or triacylglycerols was negligible. The results obtained with this kinetic spectrophotometric assay, performed with an Eppendorf ACP 5040 analyzer, agreed well with the procedure of Jaff#{233}, as modified by...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -