Comparing different methods of activating the variable stiffness function of a pediatric variable stiffness colonoscope.

نویسندگان

  • Yu-Hsi Hsieh
  • An-Liang Zhou
  • Hwai-Jeng Lin
چکیده

BACKGROUND Previous studies on variable stiffness colonoscopes showed mixed results. Different methods of activating the variable stiffness function were used and might explain part of the controversy. To determine the most efficient way of activating the variable stiffness function, this study compared 3 methods (no activation, regular activation, activation on an as-needed basis) using 1 single type of pediatric variable stiffness colonoscope. METHODS Asymptomatic patients admitted for physical check-up at the Buddhist Dalin Tzu Chi General Hospital were included. A single endoscopist performed all of the colonoscopic examinations of patients under sedation using a variable stiffness pediatric colonoscope. Consecutive patients were randomized to undergo colonoscopy using 3 different methods of activating the variable stiffness function: no activation ("no" group), regular activation at descending colon ("regular" group), and activation on an as-needed basis ("as-needed" group). Completion rate, cecal intubation time, and use of adjunct measures were evaluated and compared among the 3 groups. Subgroup analysis by gender was also performed. RESULTS Between January and July 2006, a total of 250 patients were enrolled. The completion rates of the examinations were 97.6%, 91.7% and 96.4% in the no, regular and as-needed groups, respectively (p = 0.17). The cecal intubation times were 5.6 +/- 2.6 minutes, 5.6 +/- 2.7 minutes and 6.2 +/- 2.3 minutes, respectively (p = 0.22). Multivariate logistic regression analysis showed that activation of the variable stiffness function regularly (odds ratio [OR], 0.53; 95% confidence interval [CI], 0.28, 0.98; p = 0.04) or on an as-needed basis (OR, 0.52; 95% CI, 0.28, 0.97; p = 0.04) were independent factors that were related with less use of abdominal pressure. When only women were considered, the completion rate was lower in the regular group (98.0%, 86.8% and 96.5%, p = 0.04). The use of abdominal pressure was more in the no group than the other 2 groups (56%, 34% and 33%, p = 0.03). When only men were considered, the cecal intubation time was longer in the as-needed group (4.6 +/- 1.4, 4.6 +/- 1.8 and 5.8 +/- 2.5 minutes, p = 0.02). The other outcomes were similar in both genders. CONCLUSION The 3 different methods did not result in significantly different completion rates or cecal intubation times. However, activation of the variable stiffness function decreased the need for abdominal pressure. When males and females were considered separately, activation of the variable stiffness function on an as-needed basis in females was the only useful setting.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors related to the effectiveness of variable stiffness colonoscope: results of a multivariate analysis.

BACKGROUND Various studies and two meta-analysis have shown that a variable stiffness colonoscope improves cecal intubation rate. However, there are few studies on how this colonoscope should be used. OBJECTIVE The aim of this study was to identify factors related to the advancement of the colonoscope when the variable stiffness function is activated. METHODS Prospective study enrolling con...

متن کامل

Free Vibration Analysis of Variable Stiffness Composite Laminates with Flat and Folded Shapes

In this article, free vibration analysis of variable stiffness composite laminate (VSCL) plates with flat and folded shapes is studied. In order to consider the concept of variable stiffness, in each layer of these composite laminated plates, the curvilinear fibers are used instead of straight fibers. The analysis is based on a semi-analytical finite strip method which follows classical laminat...

متن کامل

Does the variable-stiffness colonoscope makes colonoscopy easier? A meta-analysis of the efficacy of the variable stiffness colonoscope compared with the standard adult colonoscope

BACKGROUND The variable-stiffness colonoscope (VSC) appears to have advantages over the standard adult colonoscope (SAC), although data are conflicting. To provide a comprehensive up-to-date review, we conducted a meta-analysis to compare the efficacies of the VSC and SAC. METHODS Electronic databases, including PubMed, EMBASE, the Cochrane library and the Science Citation Index, were searche...

متن کامل

Free vibration analysis of variable stiffness composite laminated thin skew plates using IGA

A NURBS-based isogeometric finite element formulation is developed and adopted to the free vibration analysis of finite square and skew laminated plates. Variable stiffness plies are assumed due to implementation of curvilinear fiberreinforcements. It is assumed due to employment of tow placement technology, in each ply of variable stiffness composite laminated plate the fiber reinforceme...

متن کامل

FRAGILITY CURVES FOR STRUCTURES EQUIPPED WITH OPTIMAL SATMDs

In this paper, a procedure has been presented to develop fragility curves of structures equipped with optimal variable damping or stiffness semi-active tuned mass dampers (SATMDs). To determine proper variable damping or stiffness of semi-active devices in each time step, instantaneous optimal control algorithm with clipped control concept has been used. Optimal SATMDs have been designed based ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the Chinese Medical Association : JCMA

دوره 71 1  شماره 

صفحات  -

تاریخ انتشار 2008