Measuring percent oxygen saturation of hemoglobin, percent carboxyhemoglobin and methemoglobin, and concentrations of total hemoglobin and oxygen in blood of man, dog, and baboon.
نویسندگان
چکیده
We used an automated four-wavelength spectrometer to measure the concentration of total hemoglobin, percent oxyhemoglobin, carboxyhemoglobin, and methemoglobin, and concentration of oxygen bound to hemoglobin in the blood of humans, dogs, and baboons under clinical and various experimental conditions. Measurements of total hemoglobin and methemoglobin with this simple method were comparable to those with standard spectrometric procedures. Carboxyhemoglobin measurements were comparable to those made with gas chromatography, and measurements of oxygen content were comparable to those made with the galvanic cell method. The new instrument is as accurate as the comparison methods used to evaluate it in all parameters, is reliable, and measurements take only 63 s per sample. In addition, it requires minimal operator training, infrequent need for calibration, and no sample preparation.
منابع مشابه
Needle aspiration in lung cancer.
and injury are well-known complications of CO poisoning, possibly more prevalent in patients with pre-existing atherosclerotic coronary artery disease. As Dr. Marius-Nunez points out, hypoxic injury is multifactorial, probably related both to CO binding to hemoglobin and also to direct cellular effects of CO. All patients with carbon monoxide exposure should undergo routine electrocardiography ...
متن کاملNeedle Aspiration in Lung Cancer
and injury are well-known complications of CO poisoning, possibly more prevalent in patients with pre-existing atherosclerotic coronary artery disease. As Dr. Marius-Nunez points out, hypoxic injury is multifactorial, probably related both to CO binding to hemoglobin and also to direct cellular effects of CO. All patients with carbon monoxide exposure should undergo routine electrocardiography ...
متن کاملRecent advances in pulse oximetry
Conventional pulse oximetry uses two wavelengths of light (red and infrared) transmitted through a finger and a photodetector to analyze arterial hemoglobin oxygen saturation and pulse rate. Recent advances in pulse oximetry include: extended analysis of the photo plethysmographic waveform; use of multiple wavelengths of light to quantify methemoglobin, carboxyhemoglobin and total hemoglobin co...
متن کاملDynamic hyperinflation, intrinsic positive end-expiratory pressure, and respiratory rate.
In reviewing the article “Methemoglobinemia: Sudden Dyspnea and Oxygen Desaturation After Esophagoduodenoscopy,” in the August 2004 issue of RESPIRATORY CARE,1 I found the article suggested that, during the esophagoduodenoscopy procedure the patient’s blood oxygen saturation (measured via pulse oximetry) began to drop rapidly, and a saturation of 54% registered on the pulse oximeter while the p...
متن کاملMethemoglobinemia and Pulse Oximetry
In reviewing the article “Methemoglobinemia: Sudden Dyspnea and Oxygen Desaturation After Esophagoduodenoscopy,” in the August 2004 issue of RESPIRATORY CARE,1 I found the article suggested that, during the esophagoduodenoscopy procedure the patient’s blood oxygen saturation (measured via pulse oximetry) began to drop rapidly, and a saturation of 54% registered on the pulse oximeter while the p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 26 9 شماره
صفحات -
تاریخ انتشار 1980