Comparison of a new desktop spirometer (Spirospec) with a laboratory spirometer in a respiratory out-patient clinic.
نویسندگان
چکیده
BACKGROUND The performance of spirometers is often evaluated under ideal conditions with computer-generated waveforms or in vivo testing with healthy subjects. Real-life conditions are less ideal because of comorbidities, age of the subjects, and a variety of air flow limitations. Evaluation of new spirometry equipment can also be performed under these less favorable conditions. The Spirospec is a new desktop spirometer that is commercially available, but its accuracy has not been evaluated in a clinical setting. OBJECTIVE Test the Spirospec with subjects with normal and pathologic pulmonary function. METHODS A group of 45 patients (mean age 38.4 years, 27 male) booked for evaluation in the pulmonary function laboratory of a tertiary care university hospital were tested with both a Spirospec and a standard Jaeger Masterlab 4.0 spirometer, according to the guidelines of the American Thoracic Society. Three subgroups (normal spirometry, obstructive air flow limitation, and restrictive air flow limitation) of 15 consecutive subjects each underwent spirometry. RESULTS Pulmonary function measurements from the Spirospec correlated closely (r = 0.95-0.99) with those from the Masterlab 4.0, showing good limits of agreement and differences between the 2 devices: forced vital capacity 0.03 L, forced expiratory volume in the first second (FEV(1)) -0.01 L, peak expiratory flow -0.41 L/s, peak inspiratory flow 0.43 L/s, forced expiratory flow at 50% of total lung capacity 0.13 L/s, and forced expiratory flow at 75% of total lung capacity 0.12 L/s. With the exception of forced vital capacity and FEV(1), these differences were statistically significant (p < 0.05). CONCLUSION The Spirospec is comparable to the Masterlab 4.0, with high accuracy for FEV(1) and forced vital capacity and clinically acceptable differences in the measured flow variables.
منابع مشابه
Reproducibility and validity of a handheld spirometer.
BACKGROUND Handheld spirometers have several advantages over desktop spirometers, but worries persist regarding reproducibility and validity of data from handheld spirometers. We undertook an independent examination of the EasyOne handheld spirometer. METHODS The laboratory testing included reproducibility and validity testing with a waveform generator. We used standard American Thoracic Soci...
متن کاملA comparison of a new transtelephonic portable spirometer with a laboratory spirometer.
The Spirophone is a new, portable transtelephonic spirometer which records the slow and the forced expiratory vital capacity tests. Data can be transmitted via the telephone to a remote receiving centre, where a volume-time curve and the flow-volume curve are displayed on screen in real time. The aim of this study was to compare the newly developed transtelephonic spirometer, with a laboratory ...
متن کاملرابطه میزان کیفوز پشتی با ظرفیت های تنفسی
Objectives: Kyphosis is a common spinal abnormality. It is thought that kyphosis has an effect on respiratory system function. The purpose of this study was to investigate the relationship between thoracic kyphosis and respiratory capacities measurement by spirometer. Materials &Methods: This is a descriptive correlational design. A total of 20 males who are matched with age and body mass inde...
متن کاملAssessment of a new transtelephonic portable spirometer.
BACKGROUND A new portable spirometer, the Spirophone, has been developed that records a subject's blow and can then transmit all the data by telephone to a receiving centre for analysis and comment. Tests of this device were undertaken to determine its accuracy and reliability. METHODS The performance of the Spirophone was tested using computer generated wave forms, by delivering blows from c...
متن کاملBacterial colonization as a potential source of nosocomial respiratory infections in two types of spirometer.
The potential risk of spirometers in the transmission of respiratory infections has not been yet established. We performed a prospective cross-sectional study to determine the rate of colonization of a water-sealed spirometer and a pneumotachograph, and the potential risk of cross-transmission of microorganisms to patients using each of these devices. Fifty four patients (aged 51 +/- 18 (mean +...