Heart Rhythm Society members' views on pacemaker and implantable cardioverter-defibrillator reuse.

نویسندگان

  • Andrew B Hughey
  • Nimit Desai
  • Timir S Baman
  • Lindsey Gakenheimer
  • Lindsay Hagan
  • James N Kirkpatrick
  • Hakan Oral
  • Kim A Eagle
  • Thomas C Crawford
چکیده

BACKGROUND Reuse of cardiac implantable electronic devices (CIEDs) may help address the unmet need among patients in low- and middle-income countries (LMICs). METHODS To examine Heart Rhythm Society (HRS) physicians' opinions regarding CIED reuse, an online survey eliciting attitudes toward CIED reuse was sent to all 3,380 HRS physician members. RESULTS There were 429 responses (response rate 13%). A large majority of respondents agreed or strongly agreed that resterilization of devices for reimplantation in patients who cannot afford new devices may be safe (370, 87%) and, if proven to be safe, would be ethical (375, 88%). A total of 340 (81%) respondents would be comfortable asking their patients to consider donating their device, and 353 (84%) would be willing to reimplant a resterilized device if it were legal. The most commonly cited concerns about device reuse were infection (270, 64%) and device malfunction (125, 29%). Respondents from the United States and Canada had more favorable impressions of device reuse than respondents from other high-income countries (P < 0.05 for three of five positive statements regarding reuse), and were less likely to cite ethical concerns (P < 0.001). However, when responses from all high-income countries were compared with lower- and upper-middle income countries, there were no significant differences in the rates of approval. CONCLUSIONS HRS survey respondents support the concept of CIED reuse for patients in LMICs who cannot afford new devices. Studies are needed to demonstrate the clinical efficacy and safety of this practice and to identify potential barriers to adoption among physicians.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Canadian Cardiovascular Society/Canadian Heart Rhythm Society position paper on implantable cardioverter defibrillator use in Canada.

The Canadian Heart Rhythm Society in conjunction with the Canadian Cardiovascular Society is committed to the promotion of evidence-based practice in Canada. Since the last Canadian guidelines on the management of sudden cardiac death were published in 2000, several well-conducted clinical trials evaluating the implantable cardioverter defibrillator have been completed and published. The Canadi...

متن کامل

The Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) Expert Consensus Statement on the Perioperative Management of Patients with Implantable Defibrillators, Pacemakers and Arrhythmia Monitors: Facilities and Patient Management

a t C r a t a R The Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) Expert Consensus Statement on the Perioperative Management of Patients with Implantable Defibrillators, Pacemakers and Arrhythmia Monitors: Facilities and Patient Management This document was developed as a joint project with the American Society of Anesthesiologists (ASA), and in collaboration with the A...

متن کامل

[Spanish implantable cardioverter-defibrillator registry. Seventh official report of the spanish society of cardiology working group on implantable cardioverter-defibrillators (2010)].

INTRODUCTION AND OBJECTIVES The authors summarize the findings of the Spanish Implantable Cardioverter-Defibrillator Registry for 2010 compiled by the Spanish Society of Cardiology Working Group on Implantable Cardioverter-Defibrillators. METHODS Members of the Spanish Society of Cardiology were prospectively surveyed; data were recorded voluntarily by each implantation team on one-page quest...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Accelerated Junctional Rhythm on a Routine Electrocardiogram: An Unusual Presentation of Cardiac Sarcoidosis

Cardiac sarcoidosis is an uncommon cause of cardiac arrhythmias and cardiomyopathy. We describe a case of cardiac sarcoidosis presenting as an accelerated junctional rhythm and complete atrioventricular (AV) block, without severe left ventricular (LV) dysfunction or pulmonary symptoms. Computer tomography (CT) of the chest and mediastinal lymph node biopsy confirmed the diagnosis. Dual-chamber ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 37 8  شماره 

صفحات  -

تاریخ انتشار 2014