3D cardiac Chemical Shift Imaging of [1-13C] hyperpolarized acetate and pyruvate in pigs

نویسندگان

  • Luca Menichetti
  • Francesca Frijia
  • Alessandra Flori
  • Vincenzo Lionetti
  • Matteo Liserani
  • Giulio Giovannetti
  • Giacomo Bianchi
  • Simone L Romano
  • Vincenzo Positano
  • Jan Henrik Ardenkjaer-Larsen
  • Rolf F Schulte
  • Fabio A Recchia
  • Luigi Landini
  • Maria Filomena Santarelli
  • Massimo Lombardi
چکیده

Background 13C Dynamic Nuclear Polarization (DNP) with rapid dissolution together with Magnetic Resonance Chemical Shift Imaging (CSI) have been used for non-invasive real-time metabolic assessment in cardiac experimental models on a clinical 3T scanner. Here, we report an in vivo comparison of hyperpolarized [1-13C] pyruvate and [1-13C] acetate perfusion and metabolism: a method based on a 3D Spiral CSI sequence is presented for obtaining spatially and spectrally-resolved information on whole heart cardiac metabolism.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DNP Methods for Cardiac Metabolic Imaging with Hyperpolarized [1-13C]pyruvate Large Dose Injection in Pigs

In this study we set up and optimized a dynamic nuclear polarization (DNP) procedure for the hyperpolarization of a large dose suitable for cardiac metabolic imaging in vivo in swine models. The dose range proposed in this study allowed chemical shift imaging of cardiac metabolism with hyperpolarized [1-C]pyruvate in pigs. We investigated the typical pattern of distribution of [1-C]pyruvate and...

متن کامل

Comparison between volume and surface coils for pig cardiac metabolism studies with hyperpolarized 13C MRS

Introduction Cardiac metabolism assessment with hyperpolarized 13C in pig models requires dedicated coils design capable to provide large sensitivity regions. This work presents a comparison between a quadrature birdcage coil and a circular coil both designed for hyperpolarized studies of the heart in large animal models with a clinical 3T scanner. The results are presented as Signal-to-Noise R...

متن کامل

Hyperpolarized 13C Metabolic MRI of the Human Heart

RATIONALE Altered cardiac energetics is known to play an important role in the progression toward heart failure. A noninvasive method for imaging metabolic markers that could be used in longitudinal studies would be useful for understanding therapeutic approaches that target metabolism. OBJECTIVE To demonstrate the first hyperpolarized 13C metabolic magnetic resonance imaging of the human hea...

متن کامل

Detection of 3D Cardiac metabolism after injection of hyperpolarized [1-13C]pyruvate

Methods Three healthy male mini-pigs (38±2 kg) were maintained under deep sedation; a dose of 20 mL of 230 mM [1-13C]pyruvate was administered over about 10 s by manual injection. Animal experiments were performed on a 3T GE Signa HDx scanner with a 13C quadrature birdcage coil. [1-13C]pyruvate was polarized using a HyperSense DNP polariser with subsequent dissolution. The final injection solut...

متن کامل

Metabolic Imaging of the Perfused Rat Heart Using Hyperpolarized [1-13C]Pyruvate

Introduction : The recent development of liquid state Dynamic Nuclear Polarization (DNP) techniques has dramatically increased the signal available from C MRS experiments and has opened up new possibilities for metabolic imaging of the heart [1]. Oxidative decarboxylation of DNP hyperpolarized [1-C]pyruvate, mediated by the pyruvate dehydrogenase (PDH) complex, is a critical reaction that produ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013