An alternative method to record rising temperatures during dental implant site preparation: a preliminary study using bovine bone.
نویسندگان
چکیده
Overheating is constantly mentioned as a risk factor for bone necrosis that could compromise the dental implant primary stability. Uncontrolled thermal injury can result in a fibrous tissue, interpositioned at the implant-bone interface, compromising the long-term prognosis. The methods used to record temperature rise include either direct recording by thermocouple instruments or indirect estimating by infrared thermography. This preliminary study was carried out using bovine bone and a different method of temperatures rising estimation is presented. Two different types of drills were tested using fluoroptic thermometer and the effectiveness of this alternative temperature recording method was evaluated.
منابع مشابه
A Two-step Method for the Preparation of Implant Recipient Site in Severe Atrophic Maxilla: A Case Report of the Alveolar Ridge Split Technique Followed by Bone Expansion
Augmentation of deficient and atrophic alveolar ridges is an important aspect of dental implant therapy with the goal of providing a functional restoration in harmony with adjacent natural dentition. Bone splitting technique is considered a distinguished augmentation method for treatment of deficient alveolar ridges. According to this procedure, the compromised alveolar ridge is opened from the...
متن کاملEffect of Implant Site Preparation by Piezoelectric and Conventional Drilling on Autograft Cell Viability: A Clinical Trial
Background and Aim: Implant site preparation with minimal trauma is an important factor in success of implant treatment and has a great effect on osseointegration. Piezoelectric bone surgery was introduced as a modern technique for micrometric osteotomy with precise, controllable action. Preservation of osteoblast cell viability is critical to achieve successful osseointegration. The present st...
متن کاملTemperature Values Variability in Piezoelectric Implant Site Preparation: Differences between Cortical and Corticocancellous Bovine Bone
PURPOSE Various parameters can influence temperature rise and detection during implant site preparation. The aim of this study is to investigate local temperature values in cortical and corticocancellous bovine bone during early stages of piezoelectric implant site preparation. MATERIALS AND METHODS 20 osteotomies were performed using a diamond tip (IM1s, Mectron Medical Technology, Carasco, ...
متن کاملThermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills.
OBJECTIVES The purpose was to assess thermal changes and drill wear in bovine bone tissue with the use of twisted stainless steel and zirconia-based drills, during implant site preparation. METHODS A total of 100 implant site preparations were performed on bovine ribs using a surgical unit linked to a testing device, in order to standardize/simulate implant drilling procedures. Bone temperatu...
متن کاملEffects of a drill diameter on the temperature rise in a bone during implant site preparation under clinical conditions.
Heat, generated during the drilling of a dental implant site preparation, leads to a temperature rise and consequently to a thermal injury of the bone tissue surrounding the implant site, which can cause the subsequent implant failure. In this article, we present new findings related to the temperature rise during implant site drilling under real conditions on a bovine rib bone specimen. The ex...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annali dell'Istituto superiore di sanita
دوره 46 4 شماره
صفحات -
تاریخ انتشار 2010