Investigation of Effective DQE (eDQE) parameters for a flat panel detector

نویسندگان

  • D. Bor
  • S. Cubukcu
  • A. Yalcin
  • O. Birgul
  • N. Marshall
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective detective quantum efficiency for two mammography systems: measurement and comparison against established metrics.

PURPOSE The aim of this paper was to illustrate the value of the new metric effective detective quantum efficiency (eDQE) in relation to more established measures in the optimization process of two digital mammography systems. The following metrics were included for comparison against eDQE: detective quantum efficiency (DQE) of the detector, signal difference to noise ratio (SdNR), and detectab...

متن کامل

Practical expressions describing detective quantum efficiency in flat-panel detectors

In radiology, image quality excellence is a balance between system performance and patient dose, hence x-ray systems must be designed to ensure the maximum image quality is obtained for the lowest consistent dose. The concept of detective quantum efficiency (DQE) is widely used to quantify, understand, measure, and predict the performance of x-ray detectors and imaging systems. Cascaded linear-...

متن کامل

Study of DQE dependence with beam quality on GE Essential mammography flat panel

This paper deals with the analysis of the behavior of objective image quality parameters for the new GE Senographe Essential FFDM system, in particular its dependence with beam quality. The detector consists of an indirect conversion a-Si flat panel coupled to a CsI:Tl scintillator. The system under study has gone through a series of relevant modifications in flat panel with respect to the prev...

متن کامل

A comparison of digital radiography systems in terms of effective detective quantum efficiency.

PURPOSE The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum effici...

متن کامل

Three-Dimensional NEQ Transfer Characteristics of Volume CT using Direct and Indirect-Detection Flat-Panel Imagers

Foremost among the promising imaging performance characteristics of cone-beam CT using flat-panel imagers is the ability to form volumetric images with soft-tissue contrast visibility in combination with sub-millimeter 3-D spatial resolution. Each of these two essential characteristics is intimately related to the spatial-frequency-dependent signal and noise transfer characteristics of the imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013