Linear inverse solutions with optimal resolution kernels applied to electromagnetic tomography.
نویسندگان
چکیده
This paper discusses the construction of inverse solutions with optimal resolution kernels and applications of them in the reconstruction of the generators of the EEG/MEG. On the basis of the framework proposed by Backus and Gilbert [1967], we show how a family of well-known solutions ranging from the minimum norm method to the generalized Wiener estimator can be derived. It is shown that these solutions have optimal properties in some well-defined sense since they are obtained by optimizing either the resolution kernels and/or the variances of the estimates. New proposals for the optimization of resolution are made. In particular, a method termed "weighted resolution optimization" (WROP) is introduced that deals with the difficulties inherent to the method of Backus and Gilbert [1967], from both a conceptual and a numerical point of view. One-dimensional simulations are presented to illustrate the concept and the interpretation of resolution kernels. Three-dimensional simulations shed light on the resolution properties of some linear inverse solutions when applied to the biomagnetic inverse problem. The simulations suggest that a reliable three-dimensional electromagnetic tomography based on linear inverse solutions cannot be constructed, unless significant a priori information is included. The relationship between the resolution kernels and a definition of spatial resolution is emphasized. Special consideration is given to the use of resolution kernels to assess the properties of linear inverse solutions as well as for the design of inverse solutions with optimal resolution kernels.
منابع مشابه
Inputs and Outputs Estimation in Inverse DEA
The present study addresses the following question: if among a group of decision making units, the decision maker is required to increase inputs and outputs to a particular unit in which the DMU, with respect to other DMUs, maintains or improves its current efficiencylevel, how much should the inputs and outputs of the DMU increase? This question is considered as a problem of inverse data envel...
متن کاملReview of Methods for Solving the EEG Inverse Problem
This paper reviews the class of instantaneous, 3D, discrete, linear solutions for the EEG inverse problem. Five different inverse methods are analyzed and compared: minimum norm, weighted minimum norm, Backus and Gilbert, weighted resolution optimization (WROP), and low resolution brain electromagnetic tomography (LORETA). The inverse methods are compared by testing localization errors in the e...
متن کاملImproving Super-resolution Techniques via Employing Blurriness Information of the Image
Super-resolution (SR) is a technique that produces a high resolution (HR) image via employing a number of low resolution (LR) images from the same scene. One of the degradations that attenuates performance of the SR is the blurriness of the input LR images. In many previous works in the SR, the blurriness of the LR images is assumed to be due to the integral effect of the image sensor of the im...
متن کاملDiscrete, 3D distributed, linear imaging methods of electric neuronal activity. Part 1: exact, zero error localization
This paper deals with the EEG/MEG neuroimaging problem: given measurements of scalp electric potential differences (EEG: electroencephalogram) and extracranial magnetic fields (MEG: magnetoencephalogram), find the 3D distribution of the generating electric neuronal activity. This problem has no unique solution. Only particular solutions with “good” localization properties are of interest, since...
متن کاملSuper-resolution of Defocus Blurred Images
Super-resolution is a process that combines information from some low-resolution images in order to produce an image with higher resolution. In most of the previous related work, the blurriness that is associated with low resolution images is assumed to be due to the integral effect of the acquisition device’s image sensor. However, in practice there are other sources of blurriness as well, inc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Human brain mapping
دوره 5 6 شماره
صفحات -
تاریخ انتشار 1997