The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

نویسندگان

  • Berna Okudan
  • Thomas C Smitherman
چکیده

Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging.

OBJECTIVES Our purpose was to describe a novel, rapid stress thallium-201 (Tl-201)/rest technetium-99m (Tc-99m) agent myocardial perfusion imaging (MPI) protocol (Tl/Tc) with a high-speed MPI scanner and to compare this protocol with a standard rest/stress Tc-99m agent protocol (Tc/Tc) with respect to image quality and radiation dosimetry. BACKGROUND Recent advances in gamma camera technology...

متن کامل

Twenty-four-hour Tl-201 delayed scan underestimates myocardial viability in patients with acute myocardial infarction after percutaneous transluminal coronary angioplasty.

BACKGROUND Myocardial viability in area at risk of acute myocardial infarction (AMI) after reperfusion therapy may be underestimated by the 24-hour images due to reverse redistribution (r-RD). METHODS Subjects were 37 AMI patients in whom Tc-99m pyrophosphate (PYP)/Tl-201 dual-isotope SPECT was positive. The 24-hour delayed scan was performed with only a Tl window. One month later, follow up ...

متن کامل

Risk assessment using single-photon emission computed tomographic technetium-99m sestamibi imaging.

OBJECTIVES This review summarizes the results of single-photon emission computed tomographic (SPECT) technetium-99m (Tc-99m) tracer imaging in patients with stable symptoms, patients with acute coronary syndromes, patients undergoing major non-cardiac surgery and patients with chest pain in the emergency department. BACKGROUND Previous studies have examined the prognostic value of stress thal...

متن کامل

Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Simultaneous acquisition of dual-isotope SPECT data offers a number of advantages over separately acquired data; however, simultaneous acquisition can result in cross-contamination between isotopes. In this work we propose and evaluate two frameworks for iterative model-based compensation of cross-contamination in dual-isotope SPECT. The methods were applied to cardiac imaging with technetium-9...

متن کامل

Mechanism for abnormal thallium-201 myocardial scintigraphy in patients with left bundle branch block in the absence of angiographic coronary artery disease.

Patients with left bundle branch block (LBBB) often show abnormal images on exercise thallium (T1)-201 scintigraphy without evidence of significant coronary stenosis. We investigated the mechanism for this phenomenon. Six patients with LBBB and without significant coronary stenosis underwent T1-201 SPECT, ECG-gated SPECT imaging with Tc-99m-methoxyisobutyl-isonitrile (MIBI), and atrial pacing s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2004