Axial length measurement techniques in pediatric eyes with cataract.

نویسندگان

  • M Edward Wilson
  • Rupal H Trivedi
چکیده

Globe axial length (AL) in children is commonly measured using either contact or immersion technique. Office measurement of AL can be difficult in young children and infants and must often be done under anesthesia in an eye that is unable to cooperate with precise fixation and centration. Contact A-scan measurements yield shorter AL, on average, than immersion A-scan measurements in pediatric eyes. This difference is mainly the result of the anterior chamber depth rather than the lens thickness value. During intraocular lens power calculation, if globe axial length is measured by the contact technique, it will result in the use of an average 1-D stronger IOL power than is actually required. This can lead to induced myopia in the postoperative refraction. In our studied patients, there was a significant difference in prediction error between contact A-scan biometry and immersion A-scan biometry. The immersion A-scan technique is recommended for pediatric IOL power calculation. We also provide a review of biometry in pediatric eyes. The overall mean AL of pediatric cataractous eyes is significantly different than the mean AL of non cataractous eyes. More importantly, the standard deviation is higher in eyes with cataract than in those without. Three phases of eye growth in children have been documented: A rapid, postnatal phase from birth to 6 months of age, followed by a slower, infantile phase from 6 to 18 months of age, and finally a slow, juvenile phase from 18 months forward. In our study, girls had shorter ALs than boys and African-American subjects had longer ALs than Caucasians. Eyes with unilateral cataract had shorter ALs than eyes with bilateral cataract during the earlier years, but had longer ALs during later childhood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Axial length in eyes with bilateral pediatric cataract at tertiary eye care center in Nepal: a preliminary report.

The aim of the study was to determine the average axial length reading of the bilateral pediatric cataract undergoing cataract surgery. Pre-operative axial length measurement was done in 80 children below 15 years who had bilateral pediatric cataract. Axial length measurement was done in 56 fellow eyes. The axial length was measured under general anesthesia with the Accutome A-scan. The mean ag...

متن کامل

The change in axial length in the pseudophakic eye compared to the unoperated fellow eye in children with bilateral cataracts.

PURPOSE To compare the change in ocular axial length of the pseudophakic eye versus the fellow eye in children with bilateral cataracts who had surgery in only one eye. METHODS In this prospective cohort study, 50 eyes of 25 children with bilateral lamellar cataracts were analyzed. A complete ophthalmic examination and evaluation of axial length measurements by contact ultrasound biometry wer...

متن کامل

Keratometry in pediatric eyes with cataract.

OBJECTIVES To report the keratometry data of pediatric cataractous eyes (randomly selected single eye of bilateral cases; cataractous eye of unilateral cases) and to compare the keratometry data of the unilateral cataractous eye with the corresponding noncataractous fellow eye. METHODS Retrospective review of preoperative data of patients who had undergone cataract surgery before 18 years of ...

متن کامل

Keratometry in eyes with bilateral pediatric cataract at tertiary eye care center in Nepal: a preliminary report.

Pre-operative keratometry measurement of the subjects was done in 80 children with bilateral congenital cataract below 15 years who had undergone pediatric cataract surgery. The objective of the study was to evaluate the average keratometry reading in Nepalese children with bilateral cataract. The keratometry reading was taken under general anesthesia with the Nidek Auto Keratometer, model KM-5...

متن کامل

Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract

PURPOSE To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract. METHODS Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III (LOCS III) and AL measurements were attem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2012