Left ventricular synchrony, torsion, and recoil mechanics in Ebstein’s anomaly: insights from cardiovascular magnetic resonance

نویسندگان

  • Michael Steinmetz
  • Simon Usenbenz
  • Johannes Tammo Kowallick
  • Olga Hösch
  • Wieland Staab
  • Torben Lange
  • Shelby Kutty
  • Joachim Lotz
  • Gerd Hasenfuß
  • Thomas Paul
  • Andreas Schuster
چکیده

BACKGROUND Disease progression and heart failure development in Ebstein's Anomaly (EA) of the tricuspid valve is characterized by both right and left ventricular (LV) deterioration. The mechanisms underlying LV dysfunction and their role in heart failure development are incompletely understood. We hypothesized that LV dyssynchrony and impaired torsion and recoil mechanics induced by paradoxical movement of the basal septum may play a role in heart failure development. METHODS 31 EA patients and 31 matched controls underwent prospective cardiovascular magnetic resonance (CMR). CMR feature tracking (CMR-FT) was performed on apical, midventricular and basal short-axis and 4D-volume analysis was performed using three long-axis views and a short axis cine stack employing dedicated software. Circumferential uniformity ratio estimates (CURE) time-to-peak-based circumferential systolic dyssynchrony index (C-SDI), 4D volume analysis derived SDI (4D-SDI), torsion (Tor) and systolic (sysTR) and diastolic torsion rate (diasTR) were calculated for the LV. QRS duration, brain natriuretic peptide, NYHA and Total R/L-Volume Index (R/L Index) were obtained. RESULTS EA patients (31.5 years; controls 31.4 years) had significantly longer QRS duration (123.35 ms ± 26.36 vs. 97.33 ms ± 11.89 p < 0.01) and showed more LV dyssynchrony (4D-SDI 7.60% ± 4.58 vs. 2.54% ± 0.62, p < 0.001; CURE 0.77 ± 0.05 vs. 0.86 ± 0.03, p < 0.001; C-SDI 7.70 ± 3.38 vs. 3.80 ± 0.91, p = 0.001). There were significant associations of LV dyssynchrony with heart failure parameters and QRS duration. Although torsion and recoil mechanics did not differ significantly (p > 0.05) there was an association of torsion and recoil mechanics with dyssynchrony parameters CURE (sysTR r = -0.426; p = 0.017, diasTR r = 0.419; p = 0.019), 4D-SDI (sysTR r = 0.383; p = 0.044) and C-SDI (diasTR r = -0.364; p = 0.044). CONCLUSIONS EA is characterized by LV intra-ventricular dyssynchrony, which is associated with heart failure and disease severity parameters. Markers of dyssynchrony can easily be quantified from CMR-FT, and may have a role in the assessment of altered cardiac function, carrying potential management implications for EA patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of intra and inter-ventricular dyssynchrony in Ebstein's anomaly using cardiovascular magnetic resonance myocardial feature tracking

Background Ebstein’s anomaly consists of varying degrees of tricuspid dysplasia and displacement into the right ventricular (RV) cavity, along with changes in ventricular function predominantly affecting the RV. Measuring alterations in contraction pattern and dyssynchrony may provide insights into ventricular performance in this disease. We sought to quantify right and left ventricular (RV and...

متن کامل

Atrio-ventricular mechanics and heart failure in Ebstein's anomaly - a cardiac magnetic resonance study

Background Ebstein’s anomaly (EA) is a rare but clinically important congenital heart disease with potential affection of right ventricular(RV), right atrial (RA), left ventricular (LV) and left atrial (LA) function that may play a role in heart failure development. Thus, we sought to assess quantitative atrial and ventricular function in EA with CMR feature tracking, and to correlate changes i...

متن کامل

Torsion of the left ventricle during pacing with MRI tagging.

The effects of different pacing protocols on left ventricular (LV) torsion were evaluated over the full cardiac cycle. A systolic and diastolic series of magnetic resonance imaging (MRI) scans were combined and used to calculate the torsion of the LV in a canine model. The asynchronous activation resulting from ventricular pacing interferes with the temporal evolution of LV torsion. The torsion...

متن کامل

The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging

Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...

متن کامل

Quantification of Left Ventricular Torsion and Diastolic Recoil Using Cardiovascular Magnetic Resonance Myocardial Feature Tracking

OBJECTIVES Cardiovascular magnetic resonance feature tracking (CMR-FT) offers quantification of myocardial deformation from routine cine images. However, data using CMR-FT to quantify left ventricular (LV) torsion and diastolic recoil are not yet available. We therefore sought to evaluate the feasibility and reproducibility of CMR-FT to quantify LV torsion and peak recoil rate using an optimal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2017