Simultaneous Detection of Food Pathogens, Staphylococcus aureus, Salmonella Enterica, Bacillus cereus and Vibrio parahaemolyticus by Multiplex Real-Time Polymerase Chain Reaction

نویسندگان

  • CHING-YANG CHENG
  • CHIN-CHENG HUANG
چکیده

The study established a multiplex real-time polymerase chain reaction (PCR) for simultaneous detection and quantitation of Staphylococcus aureus, Salmonella Enterica, Bacillus cereus and Vibrio parahaemolyticus in the same reaction at one time, thus reducing the amounts of reagents and cutting down on the labor and time. Four sets of genetic marker specific primers corresponding to SAOUHSC_02297, invA, hbl and tlhA gene, and probes were labeled with FAM, HEX, TEXAS RED and Cy5 respectively. Multiplex real-time PCR was carried out with an iQTM Multiplex Powermix Kit (BIO-RAD) Sequence Detection System. The result showed that the correlation coefficient between multiplex real-time PCR estimates and plate counts of 10-serial dilutions in specific bacteria was above 0.98, independent of 101-4-fold numbers of three other pathogenic strains. With optimized conditions, the lowest detection concentrations of four pathogens were 102.5 CFU/mL for Sta. aureus, S. Enterica and V. parahaemolyticus and 103.5 CFU/mL for B. cereus. The duration of the entire experiment from DNA isolation and purification to PCR amplification was less than 12 h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Detection of Listeria monocytogenes, Escherichia coli O157:H7, Bacillus cereus, Salmonella spp., and Staphylococcus aureus in Low-fatted Milk by Multiplex PCR

A rapid and specific PCR assay for the simultaneous detection of Listeria monocytogenes, Escherichia coli O157:H7, Bacillus cereus, Salmonella spp., and Staphylococcus aureus in foods was developed to reduce the detection time and to increase sensitivity. Multiplex PCR developed in this study produced only actA, fliC, hbl, invA, ileS amplicons, but did not produce any non-specific amplicon. The...

متن کامل

Prevalence of Listeria monocytogenes, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella spp. in seafood products using multiplex polymerase chain reaction.

Although several etiological agents can be transmitted through seafood consumption, Listeria monocytogenes, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella spp. are considered among the most important pathogens in terms of public health and disease. In this study, multiplex polymerase chain reaction (PCR), as a rapid and cost-effective method, was used to determine the prevalence...

متن کامل

Rapid separation and concentration of food-borne pathogens in food samples prior to quantification by viable-cell counting and real-time PCR.

Buoyant density gradient centrifugation has been used to separate bacteria from complex food matrices, as well as to remove compounds that inhibit rapid detection methods, such as PCR, and to prevent false-positive results due to DNA originating from dead cells. Applying a principle of buoyant density gradient centrifugation, we developed a method for rapid separation and concentration followin...

متن کامل

A multiplex real-time PCR for differential detection and quantification of Salmonella spp., Salmonella enterica serovar Typhimurium and Enteritidis in meats

Salmonella (S.) Typhimurium and S. Enteritidis are the major causative agents of food-borne illnesses worldwide. Currently, a rapid detection system using multiplex real-time polymerase chain reaction (PCR) has been applied for other food-borne pathogens such as Escherichia coli, Staphylococcus aureus and Streptococcus spp. A multiplex real-time PCR was developed for the simultaneous detection ...

متن کامل

A study on the minimum inhibitory concentration and minimum bactericidal concentration of Nano Colloidal Silver on food-borne pathogens

In the emerging issue of increased multi-resistant properties in foodborne pathogens, silver nano particles are being used increasingly as antimicrobial agents. Thus, the minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of Nano Colloidal Silver towards food-borne pathogens such as Escherichia coli O157:H7, Listeria monocytogenes, Salmonella enterica Serovar Ty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012