High-Energy Resolution Microcalorimeter EDS System for Electron Beam Excitation

نویسندگان

  • A. Nagata
  • N. Sasayama
  • M. Ikeda
  • A. Odawara
  • S. Nakayama
چکیده

We have developed a microcalorimeter energy dispersive spectroscopy (EDS) system with high-energy resolution to analyze the composition in the materials with low voltage excitation. This system is based on the dilution refrigerator and has a snout like conventional EDS system. The energy resolution was 14.2 eV for Al-Kα line (1.5 keV) and the estimated count rate was 333 cps. We demonstrated the measurement of the energy spectra for three samples. A conventional EDS cannot separate between the Si-Kα (1470 eV) and W-Mα (1775 eV) lines. This separation is important in the semiconductor application and is one of the most difficult separation for the composition analysis. Our microcalorimeter EDS system could separate these peaks clearly for the WSi2 film (300 nm thickness) deposited on the silicon wafer when the excitation voltage was 5 kV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Analysis of Particles at Low Accelerating Voltages (≤ 10 kV) With Energy Dispersive X-Ray Spectroscopy (EDS)

In recent years, there have been a series of advancements in electron beam instruments and x-ray detectors which may make it possible to improve significantly the quality of results from the quantitative electron-probe analysis of individual particles. These advances include: (1) field-emission gun electron beam instruments such as scanning electron microscopes (FEG-SEMs) that have high brightn...

متن کامل

Interdisciplinary X-Ray Microanalysis: From Planets and Comets to Artifacts and Fine Art

A cryogenic microcalorimeter x-ray spectrometer is coupled to an FEI XL30 environmental scanning electron microscope (ESEM). The microcalorimeter is designed to obtain high resolution broadband xray spectra in the energy range of 150 eV to 10 keV. An x-ray optic enhances the solid angle for x-ray energies between 150 eV and 2300 eV. This enables precise microanalysis with relatively low energy ...

متن کامل

Laboratory Astrophysics Survey Of Key X-Ray Diagnostic Lines Using A Microcalorimeter On An Electron Beam Ion Trap

Cosmic plasma conditions created in an Electron Beam Ion Trap (EBIT) make it possible to simulate the dependencies of key diagnostic X-Ray lines on density, temperature, and excitation conditions that exist in astrophysical sources. We used a microcalorimeter for such laboratory astrophysics studies because it has a resolving power .1000, quantum efficiency approaching 100% and a bandwidth that...

متن کامل

Quantitative Analysis with the Transition Edge Sensor Microcalorimeter X-ray Detector

The use of a microcalorimeter X-ray detector with a transition edge sensor in an electron probe to perform quantitative analysis is reported. Two bulk samples of multielement glasses that have been previously characterized by chemical methods for use as standard reference materials were analyzed. The spectra were analyzed against standards using three different correction schemes. In one of the...

متن کامل

Ultra High Solid Angle EDS System Advanced STEM Analysis for FE-SEM

EDS (Energy dispersive X-ray spectrometry) is a technique used for elemental analysis of a sample, through detection of characteristic X-rays generated from a sample impacted by an electron beam. STEM (Scanning Transmission Electron Microscopy) is a method to obtain high spatial resolution images with Z-contrast [1]. STEM-in-SEM has recently become a technique of choice for high spatial resolut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008