Method for calculating confidence intervals for phase contrast flow measurements
نویسندگان
چکیده
BACKGROUND Phase contrast (PC) measurements play an important role in several cardiovascular magnetic resonance (CMR) protocols but considerable variation is observed in such measurements. Part of this variation stems from the propagation of thermal noise from the measurement data through the image reconstruction to the region of interest analysis used in flow measurement, which limits the precision. The purpose of this study was to develop a method for direct estimation of the variation caused by thermal noise and to validate this method in phantom and in vivo data. METHODS The estimation of confidence intervals in flow measurements is complicated by noise correlation among the image pixels and cardiac phases. This correlation is caused by sequence and reconstruction parameters. A method for the calculation of the standard deviation of region of interest measurements was adapted and expanded to accommodate typical clinical PC measurements and the region-of-interest analysis used for such measurements. This included the dependency between cardiac phases that arises due to retrospective cardiac gating used in such studies. The proposed method enables calculation of standard deviations of flow measurements without the need for repeated experiments or repeated reconstructions. The method was compared to repeated trials in phantom measurements and pseudo replica reconstructions of in vivo data. Three different flow protocols (free breathing and breath hold with various accelerations) were compared in terms of the confidence interval ranges caused by thermal noise in the measurement data. RESULTS Using the proposed method it was possible to accurately predict confidence intervals for flow measurements. The method was in good agreement with repeated measurements in phantom experiments and there was also good agreement with confidence intervals predicted by pseudo replica reconstructions in both phantom and in vivo data. The proposed method was used to demonstrate that the variation in cardiac output caused by thermal noise is on the order of 1% in clinically used free breathing protocols, and on the order of 3-5% in breath-hold protocols with higher parallel imaging factors. CONCLUSIONS It is possible to calculate confidence intervals for Cartesian PC contrast flow measurements directly without the need for time-consuming pseudo replica reconstructions.
منابع مشابه
سری آمار: تحلیل جداول توافقی 3 (معیارهای تاثیر و توافق)
In medical studies, measures are required to reveal the effect of exposures and interventions and also the precision of measurements. This paper aimed to introduce the measures of effect and agreement and inferences about them in these studies. Principles and method of calculating measures of effect and agreement and inference about them were presented for all types of medical studies taking in...
متن کاملContrasting Diversity Values: Statistical Inferences Based on Overlapping Confidence Intervals
Ecologists often contrast diversity (species richness and abundances) using tests for comparing means or indices. However, many popular software applications do not support performing standard inferential statistics for estimates of species richness and/or density. In this study we simulated the behavior of asymmetric log-normal confidence intervals and determined an interval level that mimics ...
متن کاملBootstrap confidence intervals of CNpk for type‑II generalized log‑logistic distribution
This paper deals with construction of confidence intervals for process capability index using bootstrap method (proposed by Chen and Pearn in Qual Reliab Eng Int 13(6):355–360, 1997) by applying simulation technique. It is assumed that the quality characteristic follows type-II generalized log-logistic distribution introduced by Rosaiah et al. in Int J Agric Stat Sci 4(2):283–292, (2008). Discu...
متن کاملSimulation of phase contrast MRI of turbulent flow.
Phase contrast MRI is a powerful tool for the assessment of blood flow. However, especially in the highly complex and turbulent flow that accompanies many cardiovascular diseases, phase contrast MRI may suffer from artifacts. Simulation of phase contrast MRI of turbulent flow could increase our understanding of phase contrast MRI artifacts in turbulent flows and facilitate the development of ph...
متن کاملSimultaneous confidence intervals that are compatible with closed testing in adaptive designs.
We describe a general method for finding a confidence region for a parameter vector that is compatible with the decisions of a two-stage closed test procedure in an adaptive experiment. The closed test procedure is characterized by the fact that rejection or nonrejection of a null hypothesis may depend on the decisions for other hypotheses and the compatible confidence region will, in general, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2014