Dynamic Pressure of Liquid Mercury Target During 800-MeV Proton Thermal Shock Tests
نویسندگان
چکیده
Described here are efforts to diagnose transient pressures generated by a short-pulse (about 0.5 microseconds) high intensity proton (~ 2 * 10 per pulse) beam. Proton energy is 800-MeV. The tests were performed at the Los Alamos Neutron Science Center Weapons Neutron Research (LANSCE-WNR). Such capability is required for understanding target interaction for the Spallation Neutron Source project as described previously at this conference. The main approach to effect the pressure measurements utilized the deflection of a diaphragm in intimate contact with the mercury. There are a wide variety of diaphragmdeflection methods used in scientific and industrial applications. Many deflection-sensing approaches are typically used, including, for instance, capacitive and optical fiber techniques. It was found, however, that conventional pressure measurement using commercial pressure gages with electrical leads was not possible due to the intense nuclear radiation environment. Earlier work with a fiber optic strain gauge demonstrated the viability of using fiber optics for this environment. I. BACKGROUND TO PRESSURE MEASUREMENT The pressure sensor design selected for this application was driven by several factors: the magnitude and duration of the pressure waves, the need for both high and low pressure measurement, and the need to use standardized, readilyavailable components. Two pressure sensors using diaphragms that were deflected according to the applied pressure were selected. The diaphragms were made from stainless steel. Diaphragm size and thickness were determined based on modeling which examined the tradeoffs between sensitivity, dynamic range, and response time. Deflection measurement was effected with a modified commercial fiber optic strain measurement system described later in this report. For both sensors, a mechanical stop prevented the diaphragm from flexing past the yield point. This corresponded to pressures of 17 MPa (2,500 psi) and 0.7 MPa (100 psi) for the highand low-pressure sensors, respectively. This is the upper bound of their measurement capability. The specific purpose of the high-pressure sensor was to diagnose the initial highpressure transient due to the instantaneous deposition of energy in the mercury fluid. The purpose of the low-pressure sensor was to investigate the possibility of detecting cavitation. These oscillations are predicted to occur at later times, after the expected first thermal shock induced expansion. There was a parallel effort to investigate the use of phosphor fluorescence as a pressure diagnostic. A phosphor was selected exhibiting approximately a one per cent signal increase per 10 MPa. It was thought that this method might provide very rapid response to pressure. The fluorescence was stimulated by a short-pulsed N2 laser of 3 ns duration. The results are summarized as follows. By examination of the fluorescence decay, no pressure fluctuations were discernible within the considerable noise that characterized the test. The minimum pressure observable would have been about 50 MPa. The dominant noise apparently was shot noise. This type of noise scales as the square root of the number of phosphorfluorescence photons arriving at the photodetector. In the future, shot noise will be reduced by increasing the amount of fluorescence arriving at the photomultiplier detector and by decreasing the response time of the detection system. We also observed occasional intense, short spikes in addition to the fluorescence signal from the phosphor. This is evidently some kind of radiation induced scintillation either of the phosphor or fiber. In such instances, however, these spikes were easily distinguishable from the laser-stimulated phosphor emission. When the fluorescence signal was subsequently improved by better laser-to-fiber coupling, the spikes were much weaker compared to the fluorescence. A more detailed report of the phosphor testing is in preparation. It was encouraging that both phosphors, europium-doped lanthanum oxysulfide and manganese-doped magnesium fluorogermanate, survived the entire test, about 40 shots, without noticeable degradation. The proton beam itself generated fluorescence that may be used for diagnostic purposes. II. FABRY-PEROT SENSING DESCRIPTION In order to measure the diaphragm deflection, a commercial fiber optic strain sensor was modified. The sensor was an F&S Inc. Fiber Optic Strain Sensor (FOSS) system . The FOSS system consists of a light source at 1310 nm that illuminates a Figure 1. Fiber Arrangement. Figure 2. Two diaphragm sensors. Figure 3. Side View of Pressure Sensor. single-mode optical fiber and a photodiode to detect light returning from the fiber. The input end fiber is terminated with an FT connector which mates with the FOSS system. The sensor end normally terminates in a specially designed capillary tubing for strain sensing purposes. The use of F&S hardware for strain sensing on two SNS targets is described elsewhere. For pressure sensing, the output end of the fiber is removed from the tubing and located a fixed distance from a diaphragm. This diaphragm flexes when the fluid on the opposite side increases in pressure. As the distance between the fiber and the diaphram changes, the amount of light reflected back into the fiber changes as well. Because the output face of the fiber is partially reflecting, a Fabry-Perot cavity is formed by it and the shiny, reflective diaphragm surface. Figure 1 illustrates the fiber in relation to the diaphragm. The light reflected from the diaphragm surface recombines and interferes with the light reflected by the fiber end such that the return signal varies sinusoidally with a period of 1⁄2 of the incident wavelength of 1310 nm. This approach is much more sensitive than non-interferometric methods. The light signal travels to the FOSS system where it is detected. The unit’s output is an electrical analogue of this signal and is directed to a digital oscilloscope which digitizes it. An IEEE 488 interface connection with a personal computer provides the means to store and subsequently analyze the signal. III. PRESSURE SENSOR AND CALIBRATION Figures 2 shows the high and low pressure sensors. They appear identical externally. Figure 3 is a side view of one of them. To construct them, first, standard vacuum flanges were machined to accommodate a 3/8” pipe. At the end of this pipe, a 3/8” Cajon TM fitting is applied in the normal manner. As it tightens, it secures the diaphragm, clamping it against the end of the pipe. The fitting and diaphragm are seen in the foreground of the figures. The optical fiber is potted with epoxy inside a smaller tube which slides inside of the 3/8” tubing. Another Cajon TM fitting in the back allows for tightening and setting of the position of this inner tube and thus establishing a fixed distance between the fiber and the back surface of the diaphragm. The flange of the sensors seen in the figures is bolted to the target such that the sensing end protrudes into the mercury. The sensors were calibrated using a hydraulic pump as the pressure source. An instrument known as the Fiberscan 2000, also made by F&S, was used to determine the fiber-todiaphragm gap. It functions similar to the FOSS system for strain or displacement measurements. In this instrument, a broad band light source illuminates the fiber. This device detects and analyzes several wavelengths of the return signal. Internal processing provides for displaying the results as strain or gap distance, as selected by the user. This component cannot be used for dynamic measurements as a reading is updated only every second. On the other hand, the FOSS system provides real time analog output which at the time of the experiment was capable of a response of in excess of 100 kHz. High Pressure Sensor: For the high pressure sensor, the gap between the fiber and the diaphragm was 260 μm and the active diameter of the diaphragm (taking account of where it was clamped) was 7.9 mm. Its thickness was 254 μm. As the diaphragm was displaced, the sinusoidal peak-to-peak voltage was about 0.7 V. Figure 4 shows a plot of diaphragm displacement versus pressure for two instances. Below 17 MPa, the calibration is repeatable and it is seen that a pressure of 7 MPa causes a diaphragm deflection of about 50 μm. For small deviations, the response is approximately 30 V/MPa. When the pressure exceeds about 17 MPa (2500 psi), there is evidently some permanent deformation of the diaphragm. This is evidenced by the decreased slope of the curve showing data taken to 35 MPa. Low pressure sensor: A high sensitivity pressure sensor which functioned at low pressure was fabricated from thinner stainless steel stock. It was constructed with a 160 μm air gap and diaphragm thickness of 51 microns and 7.9 mm in diameter. For small displacements, the response was about 5000 V/MPa. The calibration curve is shown in Figure 5. Data was acquired by cycling up in steps of about 70 kPa (10 psi). It is evident that the diaphragm was not flexed past its elastic limit. A pressure of about 140 kPa (20 psi) causes the diaphragm to deflect about 25 μm. For the LANSCE test, the diaphragm was prevented from flexing at pressures greater than 1.0 MPa (150 psi) in order to preserve the sensor. IV. RESULTS OF PRESSURE MEASUREMENT Figure 6 shows a sketch of the back end of Target A (TA). It is a bullet-shaped container of stainless steel, 10 cm in diameter, about 15 cm long, and with a 5-cm radius hemispherical shell at the forward end. The high and low pressure sensors were located at flange P3 and P4, respectively. Over the course of the test, the target was irradiated over thirty times with a proton beam. All data sets were labelled sequentially such that TA-12 indicates proton shot number 12 for Target A. For the high pressure diaphragm sensor, measurements were made for pulses TA-12 to TA-14 and pulses TA-25 through TA-31. For the former group, the FOSS system with frequency response of approximately 100 kHz was used. Subsequent to the test, it was discovered that the response of another FOSS system which was used for the second set of tests was, unfortunately, only about 20 kHz (This was due to some internal electronic settings inside the unit. The settings were corrected after this series of tests). For each of shots TA-12 to TA-14, the incident number of protons was 2.3x10. The analysis of this data is very difficult. Keep in mind that as the distance of the gap changes (monotonically), the detected signal varies sinusoidally. Once a local maximum in pressure is reached, signal from that point will continue a sinusoidal dependence, simply retracing the part of the cycle it was in. In order to estimate the maximum displacement, the point of this reversal must be determined. The displacement is the total number of cycles (ie. fringes) times half the wavelength of the light source. For slowly varying signals, identifying the turnaround points can be straightforward. For much of the rapidly fluctuating data acquired in this test, reliable determination of the turning point is not possible. There are several useful observations that can be made, however. Figure 7 shows time versus diaphragm displacement for TA-12 for a period of about 14 ms after the shot. The signal varies more rapidly at early times than later times. This means the pressure rises and decreases more rapidly at earlier times, whatever the magnitude may be. Clearly the signal versus time as seen in the figure is complex, rendering determination of the turn-around points very difficult for most of the signal. If the signal reached a maximum or minimum, that would have meant that the physical limit of flexure had been reached. This was not the case, therefore, it is a safe assumption that the pressure never exceeded 17 MPa, the pressure at which a physical stop prevents further flexure. A comparison of data from TA-12-14 shows that the sensor response is reproducible. This is seen in Figure 8. The data of TA-12 and TA-13 were not taken for as long a period of time after the shot as TA-14, as it turned out. This is the reason for the difference in length of each of the plots in that figure. Figure 9 shows data from shot TA-14 from the time period of about 25 to 90 ms after the shot. The data for the first 25 ms is similar to that above for TA-12. But during the later time, as is depicted in Figure 9, the pressure has decreased to where the signal varies within the peak-to-peak sinusoidal-displacement period. The maximum and minimum signal are less than the peak-to-peak signal for this sensor. Thus, in this region the signal can be processed using an appropriate arcsin relationship between the time and the displacement. Then, noting from the calibration data that the dependence is 0.14 kPa/nm, a plot of pressure versus time is obtained. The processed signal shown in Figure 9 reveals the pressure ranging from -5 to 15 kPa and gradually decaying to a few kPa. The fact that it is not precisely zero means that the diaphragm, once it ceased vibrating, returned to a final position that was different by a few nm. Figure 10 shows representative data for the low-operating pressure, high sensitivity sensor. It is seen that, for pulse TA35, for the first 1 ms the sensor quickly reaches a maximum and swings to the opposite extreme. This means the diaphragm during this portion of test flexed to its physical limits. After that time, the signal varied by a volt or less. For times after 1 ms, the voltage axis could be scaled by the 5000 V/MPa calibration factor to yield pressure versus time as seen in the figure. The meaning of these sub-kPa pressure fluctuations are difficult to assess. At very long times, up to 16 ms, pressure waves are detectable, but are very low in amplitude.
منابع مشابه
Measurement of Dynamic Strain on a Mercury Target Vessel During 800-MeV Proton Thermal Shock
A mercury target vessel, designed to simulate some aspects of the eventual target design for the proposed Spallation Neutron Source (SNS) to be built in Oak Ridge by the Department of Energy, was used in a test at the Los Alamos Neutron Science Center (LANSCE) to study the strain induced from thermal shock of bombarding protons. In the SNS, intense thermal shock loads are expected to cause an e...
متن کاملTargetry for cyclotron production of no-carrier-added cadmium-109 from natAg(p,n)109Cd reaction
Background: Solid targets that consist of powder and electrodeposited targets are used commonly to produce radionuclides by accelerators. Since silver is easily electrodeposited in cyanide baths and has a very excellent thermal conductivity, the electrodeposited target is preferable to produce 109Cd. To avoid cracking or peeling of the target during bombardment, it should have a level surface a...
متن کاملTwo-phase flow model for energetic proton beam induced pressure waves in mercury target systems in the planned European Spallation Source
Two-phase flow calculations are presented to investigate the thermo-hydraulical effects of the interaction between 300 kJ proton pulses (2 ms long, 1.3 GeV) with a closed mercury loop which can be considered as a model system of the target of the planned European Spallation Source(ESS) facility. The two-fluid model consists of six first-order partial differential equations that present one dime...
متن کاملExperimental observation of proton-induced shocks and magneto-fluid-dynamics in liquid metal
A liquid metal target is one of the options for the pion production target of a n-factory. The interaction between a liquid metal and a proton beam were observed with static mercury as well as with a free mercury jet and up to 4 10 protons/bunch. The experimental method for investigating the magneto-fluid-dynamic effects of a high-velocity liquid metal in a high magnetic field magnet has been v...
متن کاملANALYSIS OF A CLAD TUNGSTEN TARGET AFTER IRRADIATION IN AN 800 MeV PROTON BEAM
For the Accelerator Production of Tritium (APT) and the Accelerator Driven Transmutation Facility (ADTF), tungsten is being proposed as a target material to produce neutrons. Previous work showed that the mechanical properties of tungsten are degraded from irradiation in a neutron flux but little work had been performed on the irradiation of tungsten in a high energy proton beam. In this study,...
متن کاملAssessment of The Relation Between Energy Of Primary Protons And Undesired Neutron Dose During Proton Therapy By Monte Carlo Method
Introduction: High-energy beams of protons offer significant advantages for the treatment of deepseated local tumors. Their physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum -Bragg peak- near the end of range with a sharp fall-off at the distal edge. Alongside its advantages there are some point that they need to meticul...