Conceptual Study of Neutron Irradiator-driven by Electron Accelerator

نویسندگان

  • D. Ridikas
  • H. Safa
چکیده

Spallation neutron sources, though very effective in neutron production, are large, expensive and presently would involve certain difficulties in their operation (e.g., beam trips). Contrary, an electron driver, although much less effective in neutron production, is rather cheap and compact machine that, at the same time, might bring advantages in terms of reliability. Here we investigate the use of an external neutron source (irradiator) driven by an electron accelerator. A schematic layout and design of a compact neutron irradiator is proposed with its neutronics and safety being analysed and discussed in detail. The system is based on a spherical geometry with an electron beam interacting with the target-envelope. Neutrons are produced in the natural or enriched uranium by photo-nuclear reactions. The system is well sub-critical (keff <0.8) and uranium enrichment is below 20%. Neutron balance is optimised by using different geometry and material configurations. Our preliminary calculations show that variable (up to 10% thermal and/or up to 30% with energies higher than 1 MeV) neutron fluxes of a few 10 n s cm could be obtained for different irradiation purposes. An electron machine of ~8 MW power and 100 MeV incident energy should be sufficient to produce external neutrons to drive the system. 1. Corresponding author’s e-mail: [email protected]; tel.: +33 1 69087847, fax: +33 1 69087584.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

Dental Materials Effect in Neutron Contamination: Electron Mode of a Linac

Background: Neutron contamination is produced in electron beams of linac when tooth or dental materials are located in the path of beam. Objective: This study aims to determine the neutron dose contamination from different dental restoration materials in electron mode of a linac. Material and Methods: In this experimental study, the neutron dose contamination was calculated in the p...

متن کامل

The Influence of Brass Compensator Thickness and Field Size on Neutron Contamination Spectrum in 18MV Elekta SL 75/25 Medical Linear Accelerator with and without Flattening Filter: A Monte Carlo Study

BackgroundOne of the most significant Intensity Modulated Radiation Therapy treatment benefits is a high target to normal tissue dose ratio. To improve this advantage, an additional accessory such as a compensator is used to delivering doses. Compensator-based IMRT treatment is usually operated with an energy higher than 10 MV. Photoneutrons, which have high linear energy transfer and radiobiol...

متن کامل

The Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator

Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...

متن کامل

Experimental and Monte Carlo evaluation of the neutron flux of an assembly with two AmBe sources.

This work aimed to determine the irradiator thermal (under-cadmium) and fast (over-cadmium) neutron fluxes, of the Nuclear Experimental Laboratory of the Nuclear Engineering Center (CNEN-IPEN, São Paulo, Brazil), and the possibility of this irradiator use for Neutron Activation Analysis (NAA), by the absolute method. To establish the facility specifications, the neutron flux values along the ir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001