Data Archiving and Retrieval for Spring-8 Accelerator Complex
نویسندگان
چکیده
The data archiving and retrieving system based on a relational database management system has successfully managed SPring-8 accelerator complex control system for two and half years. The scalability of the database system is flexible enough to require no major modification on the database for the addition of accelerator subsystems. We describe the database system focused on data access methods in data archival and retrieval.
منابع مشابه
The first operation of control system at the SPring-8 storage ring
The control system based on the standard model of the UNIX and VMEbus system has successfully performed accelerator operation with 8GeV electron beams. The software architecture of the control system designed with the client/server scheme has well operated over the distributed computing environment with the FDDI opticalfiber network. The relational database system has been widely used for machi...
متن کاملRECENT PROGRESS OF THE SPring-8 FACILITY
Since October 1997, the SPring-8 facility has been operated well and provided high quality photon beams for users. Over this period, various kinds of improvements have been carried out to achieve brilliant and stable photon beams and to make the most of 8-GeV potentiality. At the same time R&D has continued for future radiation sources. In these activities, the largest achievement has been the ...
متن کاملMonte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy
Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...
متن کاملUpgrade of Linac Control System with New Vme Controllers at Spring-8
We integrated an injector linac control system to the SPring-8 standard system in September 2000. As a result of this integration, the SPring-8 accelerator complex was controlled by one unified system. Because the linac was continuously running as the electron beam injector not only for the SPring-8 storage ring but also for NewSUBARU, we had to minimize the hardware modification to reduce the ...
متن کاملبررسی الگوی خود-آرشیوی نویسندگان ایرانی: مقایسه حوزه های علوم و علوم اجتماعی
Purpose: This research is devoted to find out the level of self-archival pattern among Iranian researchers with high rate of publications, based upon the ISI citation indices in the scopes of science and social sciences. Methodology: This research is a descriptive survey based on observation. The necessary data was obtained through observing the websites of the 80 Iranian researchers with high...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999