Spatial dependence of the nonlinear BOLD response at short stimulus duration.

نویسندگان

  • Josef Pfeuffer
  • Jeffrey C McCullough
  • Pierre Francois Van de Moortele
  • Kamil Ugurbil
  • Xiaoping Hu
چکیده

Most functional magnetic resonance imaging studies use linear models to predict the measured response by convolution of an impulse response with the stimulus profile. Using very short visual presentation times (<2 s), deviation from the linear model in the measured BOLD data from the human brain was found for the response integral, amplitude, and width. In this study, high temporal and spatial resolution were used to quantify nonlinear effects and investigate the spatial dependence. Data at 4 Tesla showed at short stimulus duration a nonlinearity, i.e., deviation from a linear model, with an index up to 400%, whereas data at 7 Tesla exhibited a nonlinearity index up to 40%. The effect was more pronounced for response amplitude than for response area. A reduced width and sharpening of responses at shorter stimulus duration was also found. A voxel-based analysis of 7 Tesla data with 1.2 x 1.2 x 2 mm(3) resolution revealed a correlation between response onset and nonlinearity index. This suggests that the nonlinearity effects are a tissue-specific phenomenon and are likely to be more localized to the site of neuronal activity. The observed magnetic field dependence and the demonstrated nonlinearity in the response width support the hypothesis that the source of the nonlinearity at short stimulus duration has a considerable hemodynamic contribution. The nonlinearity was modeled as a "switch"-type initial hemodynamic response onset. Understanding these nonlinearities in the BOLD response is important for design and the analysis of rapid event-related fMRI experiments with brief stimulus presentations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Communication Spatial dependence of the nonlinear BOLD response at short stimulus duration

Most functional magnetic resonance imaging studies use linear models to predict the measured response by convolution of an impulse response with the stimulus profile. Using very short visual presentation times ( 2 s), deviation from the linear model in the measured BOLD data from the human brain was found for the response integral, amplitude, and width. In this study, high temporal and spatial ...

متن کامل

Spatial heterogeneity of the nonlinear dynamics in the FMRI BOLD response.

Recent studies of blood oxygenation level dependent (BOLD) signal responses averaged over a region of interest have demonstrated that the response is nonlinear with respect to stimulus duration. Specifically, shorter duration stimuli produce signal changes larger than expected from a linear system. The focus of this study is to characterize the spatial heterogeneity of this nonlinear effect. A ...

متن کامل

Non-Linearities of the BOLD Response in the Human Brain

In this study, event-related functional magnetic resonance imaging (fMRI) studies were performed on healthy volunteers at 7 Tesla (T), the highest field strength currently available for human studies. This study assessed the linearity of the hemodynamic response to short-duration stimuli of 0.25s, 0.5s, 1.0s, and 2.0s. This study expected clearer resolution at 7T. Results showed that the hemody...

متن کامل

Stimulus frequency dependence of blood oxygenation level-dependent functional magnetic resonance imaging signals in the somatosensory cortex of rats.

Understanding the mechanism of coupling between neuronal events and hemodynamic responses is important in non-invasive functional imaging of the brain. The stimulus frequency dependence of hemodynamic responses has been studied using a rat somatosensory cortex model; most results for short stimulus durations reveal peak frequencies at which the hemodynamic response is maximized. However, such p...

متن کامل

Dynamics and nonlinearities of the BOLD response at very short stimulus durations.

In designing a functional imaging experiment or analyzing data, it is typically assumed that task duration and hemodynamic response are linearly related to each other. However, numerous human and animal studies have previously reported a deviation from linearity for short stimulus durations (<4 s). Here, we investigated nonlinearities of blood-oxygenation-level-dependent (BOLD) signals followin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 18 4  شماره 

صفحات  -

تاریخ انتشار 2003