Hypo‐Attenuated Leaflet Thickening and Reduced Leaflet Motion in Sutureless Bioprosthetic Aortic Valves

نویسندگان

  • Magnus Dalén
  • Ulrik Sartipy
  • Kerstin Cederlund
  • Anders Franco‐Cereceda
  • Anders Svensson
  • Raquel Themudo
  • Peter Svenarud
  • Elin Bacsovics Brolin
چکیده

BACKGROUND The prevalence of hypo-attenuated leaflet thickening (HALT) and reduced leaflet motion (RLM) is unknown in surgically implanted bioprostheses because systematic investigation of HALT and/or RLM is limited to a few catheter-based valves. The aim of this study was to investigate the prevalence of HALT and RLM by cardiac computed tomography in patients who underwent surgical aortic valve replacement and received a Perceval sutureless aortic valve bioprosthesis. METHODS AND RESULTS This was a single-center prospective observational study that included 47 patients (83.5% of the total number of implantations) who underwent surgical aortic valve replacement with implantation of the Perceval sutureless bioprosthesis (LivaNova PLC, London, UK) at Karolinska University Hospital in Stockholm, Sweden from 2012 to 2016 and were studied by cardiac computed tomography. Cardiac computed tomography was performed at a median of 491 days (range 36-1247 days) postoperatively. HALT was found in 18 (38%) patients and RLM in 13 (28%) patients. All patients with RLM had HALT. Among patients with HALT, 5 out of 18 patients (28%) were treated with anticoagulation (warfarin or any novel oral anticoagulant) at the time of cardiac computed tomography. Among patients with RLM, 3 out of 13 patients (23%) were treated with anticoagulation. CONCLUSIONS HALT and RLM were prevalent in the surgically implanted Perceval sutureless aortic valve bioprosthesis. Both HALT and RLM were found in patients with ongoing anticoagulation treatment. Whether these findings are associated with adverse events needs further study. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02671474.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subclinical Valve Thrombosis in Sutureless Bioprosthetic Valves

I n the current issue of JAHA, Dal en et al 1 report the results of a single-center prospective observational study of 47 patients with implantation of the Perceval sutureless bioprosthesis (LivaNova, Milan, Italy). Cardiac computed tomography (CT) performed at a median of 491 days (range 36– 1247 days) found hypo-attenuated leaflet thickening (HALT) in 18 (38%) and reduced leaflet motion (RLM)...

متن کامل

Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves.

BACKGROUND A finding of reduced aortic-valve leaflet motion was noted on computed tomography (CT) in a patient who had a stroke after transcatheter aortic-valve replacement (TAVR) during an ongoing clinical trial. This finding raised a concern about possible subclinical leaflet thrombosis and prompted further investigation. METHODS We analyzed data obtained from 55 patients in a clinical tria...

متن کامل

Vibrational analysis of bioprosthetic heart valve leaflets using numerical models: effects of leaflet stiffening, calcification, and perforation.

The fundamental natural frequency of the closed cusps of porcine bioprosthetic valves, fabricated from the normal leaflets of pig aortic valves, was estimated using a finite element model. Both normal and stiffened leaflets were considered in the vibrational analysis. The effects of conditions that simulated degeneration, such as stiffening, central perforation, a tear, calcium deposits in the ...

متن کامل

Pregnancy-induced remodeling of heart valves.

Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional ...

متن کامل

Aortic Valve Leaflet Motion during Systole

An approximate numerical^graphical solution was made for the motion of a human aortic valve leaflet in a meridional plane through the center of the sinus of Vabalva. The observed buckling, whipping action of the leaflet was obtained. Of primary significance in the results was the location and the determination of the maximum curvature of the leaflet in this plane, since this point corresponds t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017