Reduction of FSE Cusp Artifact Using Slice Tilting

نویسندگان

  • N. Rangwala
  • X. J. Zhou
چکیده

Introduction With specific combinations of B0-field, B1-field, and gradient field, peripheral signals outside the prescribed field of view (FOV) can fold back onto the image, resulting in a bright spot, a series of spots, a band, or a “feather-like” artifact along the phase encoding direction. In a fast spin echo (FSE) image, this type of artifact has been termed as cusp artifact [1,2], annefact, fold-over artifact, feather artifact, and other names. It is most commonly seen on sagittal (or coronal) spine or knee images. With the present trend of short magnets in whole-body scanner designs, the problem of the FSE cusp artifact becomes increasingly important. Current approaches to attack this problem involve substantial hardware modification [3], sophisticated image reconstruction [4-5], or use of metal shields which may cause localized RF power deposition. These approaches, while effective, may not be easily implementable on all MRI scanners. We propose a technique to reduce the FSE cusp artifact by a simple pulse sequence modification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of fast spin echo cusp artifact using a slice-tilting gradient.

A "featherlike" artifact, termed a cusp artifact, is sometimes seen along the phase-encoding direction in sagittal or coronal fast spin echo images. This artifact arises from the spins, at a location distant from the magnet isocenter, that are excited and aliased to the field of view because their precession frequency is similar to those at the isocenter. Such a situation is created due to a co...

متن کامل

The FSE Cusp Artifact: A Phase Wrap-In Artifact Seen on Routine Clinical MR Images of the Knee

In the course of routine fast spin echo (FSE) magnetic resonance (MR) imaging of knees, we have noticed a distinct and recurrent artifact on MR sagittal knee images. The artifact usually appears as a focal dot of high signal intensity and/or c-shaped ripples at a non-orthogonal angle (Figure 1). The technical features of this artifact have been previously described in an ISMRM abstract in 1995,...

متن کامل

Comparison of optimized fast spin echo (FSE) magnetic resonance (MR) imaging to view angle tilt (VAT) FSE in the reduction of metallic susceptibility artifact surrounding arthroplasty

Introduction / Background: MR imaging of arthroplasty has traditionally been limited by the presence of artifact generated by the metallic components, which comparatively demonstrate higher magnetic susceptibility than the adjacent bone and soft tissue (1-3). The sources of these artifacts include induction of radiofrequency eddy currents in the metal, warping of the slice during slice selectio...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Increasing parallel imaging performance and correcting field inhomogeneity artifact in MS-CAIPIRINHA using view angle tilting technique (CAIPI-VAT)

Purpose: To increase parallel imaging performance in multi-slice controlled aliasing in parallel imaging and to reduce field inhomogeneity artifact using view angle tilting technique. Methods: Controlled aliasing in parallel imaging (CAIPI) 2 technique makes each excited slice shift along phase encoding (PE) direction by inducing linear phase using different RF phase at each slice. Then the coi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008