Modelling of Downhole Seismic Sources Ii: an Analysis of the Heelan/brekhovskikh Results and Comparison of Point Source Radiation to Radiation from Boreholes
نویسندگان
چکیده
The work of Heelan (1952, 1953a,b) was one of the first studies of wave propagation from a cylindrical boundary. Heelan attempted to model the radiation emanating from a cylindrical shot hole filled with dynamite. To do so he applied a constant stress to a finite length of an empty infinite cylindrical cavity embedded in an infinite elastic, homogeneous medium. The stresses he considered were axial, torsional, and radial stresses. The radial and axial stresses were required to be proportional to each other and of the same duration. To date Heelan's work has been referenced in over 100 articles and 15 different journals including recent works (Paulsson, 1988) . His results have also been compared with results from the reciprocity theorem (White, 1953, 1960) and played an integral part of important books including those by Brekhovskikh (1960, 1980) and White (1965, 1983). His fundamental contributions were the description of shear wave lobes, the famous four-leaved rose, generated from a radial source in a borehole and that the radiation patterns for an axial source and a torsional source in a borehole have the same geometries as the point axial and torsional sources in infinite media. Despite the importance of this work, Heelan's results have been criticized by Jordan (1962) who dismissed the work as mathematically unsound and Abo-Zena (1977) who devoted an appendix of his 1977 paper to criticizing Heelan's results. The main point of contention has been the use of contour analysis in his first paper (Heelan, 1953a). Although Heelan's work did not include a fluid-filled borehole which is a crucial
منابع مشابه
Investigation of Anisotropy Caused by Cylinder Applicator on Dose Distribution around Cs-137 Brachytherapy Source using MCNP4C Code
Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive sp...
متن کاملAssessment of radioactive contamination in water bodies around mine workings using radiation counter
The vulnerability of water bodies to contamination within the neighbourhood of open mine cast environ cannot be overemphasized. Evidence of radioactive trace elements associated with the target minerals in the Plateau State (Nigeria) showed the extent of this vulnerability. In order to address this challenge, the radioactivity levels of water samples from mine ponds, streams, wells, and borehol...
متن کاملRecent developments in brachytherapy source dosimetry
Application of radioactive isotopes is the treatment of choice around the globe for many cancer sites. In this technique, the accuracy of the radiation delivery is highly dependent on the accuracy of radiation dosimetry around individual brachytherapy sources. Moreover, in order to have compatible clinical results, an identical method of source dosimetry must be employed across the world. This ...
متن کاملSkin Dosimetry of Some Beta Sources using the VARSKIN2 Code
Introduction: Skin dose and depth dose distribution of some beta sources that can contaminate skin or protective clothing covering the skin have been calculated using VARSKIN2. Materials and Methods: In this research, absorbed dose to skin and depth dose from the skin surface have been calculated for 90Sr/90Y, 147Pm, 32P beta emitter radioisotopes by using input parameters: activity of source, ...
متن کاملDetermination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods
High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -