Biological equivalent dose prediction in pion irradiation using pion star density and the mixed beam lesion additivity model.
نویسنده
چکیده
The biological equivalent dose profile of the pion beam was predicted with one parameter (gamma) using physical dose and pion star density. The value of the relative biological effectiveness (RBE) at each depth was given as a linear function of pion star density (PSD): RBE = 1.0 + gamma PSD, assuming (i) the mixed beam lesion additivity model and (ii) the linear relationship between the ratio of high LET dose to total dose and pion star density. The predicted depth-survival curve fitted well with the pooled biological data of the gel technique using Chinese hamster cells (CHO). The predicted RBE were consistent with previously published results through the flat dose peak, except at the decreasing portion of the dose profile. The practical usefulness of this model in clinical treatment is stressed.
منابع مشابه
Mammalian cell survival studies characterizing multiport negative pi-meson irradiation with the Stanford Medical Pion Generator (SMPG).
Radiobiological measurements have been made under various conditions of muliport pion irradiation using the Stanford Medical Pion Generator (SMPG). Chinese hamster cells (HA-1) were suspended in a tissue-equivalent 25% gelatin/medium solution. Hypoxic and aerobic HA-1 cells were irradiated simultaneously in a cylindrical water tank at either 4 or 16 degrees C. Irradiation at the focus of 60 con...
متن کاملCalculation of absorbed dose in lung tissue equivalent and compared it with prediction of a treatment planning system using Collapsed Cone Convolution algorithm
External radiotherapy is used for treatment of various types of cancers. Due to the impossibility of measuring the absorbed dose delivered to different organs during irradiation, treatment planning systems (TPSs) have been utilized for calculation of absorbed dose before a radiotherapy procedure. Thus, the accuracy and precession of the TPS is essential.The aim of this study is investigation of...
متن کاملHeavy particles in therapy: an application of track theory.
The survival, OER, and RBE for HeLa, leukemia, and kidney cells after irradiation with 14 MeV neutrons, pion beams, and heavy ion beams dispersed by ridge filters are calculated. Simple beam models and the delta-ray theory of cellular survival are used in the calculations, which refer to a mixed radiation environment and the potential application of these irradiation systems in radiotherapy.
متن کاملNONDYNAMICAL ANALYSIS OF SPIN AMPLITUDES IN PION-PROTON ELASTIC SCATTERING IN OPTIMAL FORMALISM AT 6.0 GeV/C
Optimal conditions are used in nondynamical formalism to diagonalize the pionproton reaction matrix as much as possible. Invariance laws are imposed to simplify the relationship between observables and bilinear combination of amplitudes. Transverse amplitudes are determined by using measured polarization parameter in xfp elastic scattering at 6.0 GeVIC
متن کاملPion Polarizabilities at CERN COMPASS
Objective: The electric (ᾱ) and magnetic (β̄) pion Compton polarizabilities characterize the pion’s deformation in the electromagnetic field of the γ during γπ Compton scattering. They depend on the rigidity of the pion’s internal structure as a composite particle. The polarizabilities deduced by Antipov et al. in their low statistics Primakoff experiment (∼ 7000 events) were ᾱπ = −β̄π = 6.8± 1.4...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 34 6 شماره
صفحات -
تاریخ انتشار 1989