s . in s - de t ] 1 1 Ju n 20 14 Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter The CALICE Collaboration

نویسندگان

  • N. Zaganidis
  • V. Zutshi
چکیده

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45×10×3 mm plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype’s performance is presented in terms of the linearity and resolution of the energy

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analyses of test beam data using the CALICE calorimeter

We discuss several features of hadronic showers recorded in the high granularity CALICE Si-W ECAL and scintillator-tile HCAL and confront them with several Geant4 physics models. The first measurements of the time-structure of hadronic showers in a tungsten scintillator calorimeter are presented. The high granularity of the CALICE calorimeters allows a software compensation which improves the e...

متن کامل

Hadronic showers in the CALICE calorimeter prototypes

The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at the future International Linear Collider. These calorimeters have been tested extensively in particle beams at CERN and at Fermilab. We present preliminary results of an analysis of hadronic events in the combined system under t...

متن کامل

The Tail-Catcher/Muon Tracker for the CALICE Test Beam

The CALICE (CAlorimeter for the Linear Collider with Electrons) collaboration [1] plans to examine several technology and geometry options for electromagnetic and hadronic calorimetry at the proposed International Linear Collider. Since in many geometries the total material thickness of the calorimeter is too little to fully contain highly energetic hadronic showers, it is important to gain a g...

متن کامل

CALICE ScECAL Beam Test at Fermilab

The scintillator-strip electromagnetic calorimeter (ScECAL) is one of the calorimeter technologies which can achieve fine granularity required for the particle flow algorithm. Second prototype of the ScECAL has been built and tested with analog hadron calorimeter (AHCAL) and tail catcher (TCMT) in September 2008 at Fermilab meson test beam facility. Data are taken with 1 to 32 GeV of electron, ...

متن کامل

Prototype Calorimeters for Linear Collider Detectors

For several years, CALICE has been testing highly granular calorimeter prototypes using analogue readout. These devices are envisaged for particle flow [1] application in a future linear collider detector. A novel alternative, especially interesting for the hadron calorimeter, is to use a simplified digital (= 1 – bit) readout coupled with very small cell sizes. In the past year the first large...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014