Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique

نویسندگان

  • Junichi Ohishi
  • Hajime Kurosawa
چکیده

BACKGROUND The forced oscillation technique (FOT) is a simple method for assessing the oscillatory mechanics of the respiratory system. The oscillatory properties, respiratory system resistance (Rrs) and reactance (Xrs), are calculated from the oscillatory pressure/flow relationship. Although the FOT has been a well-established technique, some detailed experimental conditions would be different among institutions. METHODS We evaluated whether time lags produced by the experimental conditions such as different positions of the sensors can affect the accuracy of the FOT. If the position of the pressure sensor is different from the flow sensor, a time lag may occur in the measurements. The effect of the time lag was studied by numerical analysis. RESULTS Rrs was estimated to be increased and Xrs decreased with an increase in the time lag, especially at a high oscillatory frequency of the medium-frequency range (5-35 Hz). At the high-frequency range (10-500 Hz), Rrs and Xrs were strikingly different in the values of the time lag. CONCLUSION A time lag between the oscillatory pressure and flow may be involved in the accuracy of the FOT, suggesting that it needs to be minimized or compensated for with signal processing. Researchers should pay attention to such detailed experimental conditions of the FOT apparatus.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Forced oscillation techniques for measuring mechanical properties of the respiratory system.

Airway function is usually assessed by tests of forced expiration or, in more specialised laboratories, by measuring airways resistance by whole body plethysmography. Plethysmography depends on the patients' cooperation and requires expensive and bulky apparatus. An alternative non-invasive technique for measuring airflow resistance, using forced oscillation, was introduced by DuBois and collea...

متن کامل

The forced oscillation technique in intubated, mechanically-ventilated patients.

In a recent discussion concerning the use of the forced oscillation technique (FOT), PRIDE [ 1] stated that, although anaesthesia and intensive care are among the obvious areas of application of the method, there is very little information on these applications. The paper by PEsuN et al. [2] in the present issue of the Journal describes one of the first attempts to apply the FOT to mechanically...

متن کامل

Effect of Amplitude and Mean Angle of Attack on the Unsteady Surface Pressure of a Pitching Airfoil

Details of pressure distributions, on a two dimensional airfoil oscillating in pitch through stall, in a 0.8 0.8 m low-speed wind tunnel are presented. Pitching occurred about the airfoils quarter-chord axis. Pitch rate, Reynolds number, and oscillation amplitudes were varied to determine the effects on pressure and lift distributions. It was found that mean angle of attack and pitching amplitu...

متن کامل

Expiratory flow limitation detected by forced oscillation and negative expiratory pressure.

The within-breath change in reactance (Delta(rs)) measured by forced oscillation technique (FOT) at 5 Hz reliably detects expiratory flow limitation in chronic obstructive pulmonary disease (COPD). The present study compared this approach to the standard negative expiratory pressure (NEP) method. In total, 21 COPD patients were studied by applying both techniques to the same breath and in 15 pa...

متن کامل

Attenuation of Oscillatory Pressures in Instrument Lines

A theoretical investigation has been made of the attenuation and lag of an oscillatory pressure variation applied to one end of a tube, when the other end is connected to a pressuresensitive element. An elementary theory based on incompressible viscous-fluid flow is first developed. The elementary solution is then modified to take into account compressibility; finite pressure amplitudes; apprec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2011