Evaluation of Micro-Media Quad Panels for identification of the Enterobacteriaceae.
نویسندگان
چکیده
The Micro-Media Quad Enteric Panel and coding system were evaluated by comparing the identifications of 193 stock and 216 clinical isolates, representing 31 species of Enterobacteriaceae, with those provided by conventional methods. The results corresponded for 91% of the organisms if only the single or most probable identification was accepted and for 93% if the correct identification was listed as one of several possible, but not the most probable, identification by the coding system. With 73% of the isolates, the single identification provided by the coding system was correct, and in 20% of instances the correct identification was listed as the first of several choices in descending order of probability but requiring additional tests for differentiation. In most of the latter instances, these additional tests consisted of serological confirmation of salmonellae or shigellae. Discrepancies consisted of incorrect identifications (4%) and organisms with code numbers not appearing in the coding system (3%).
منابع مشابه
Rapid identification of Enterobacteriaceae with the micro-ID system versus API 20E and conventional media.
The Micro-ID system for rapid (4 h) identification of Enterobacteriaceae was evaluated by testing 433 enteric bacilli and 9 other gram-negative bacilli. Each isolate was identified with conventional tubed media and was also tested in the Micro-ID and API 20E systems. The overall accuracy of both systems was 97%. Micro-ID tests for the Voges-Proskauer reaction, indole and H2S production, and orn...
متن کاملComparison of Micro-ID and API 20E systems for identification of Enterobacteriaceae.
The Micro-ID 4-h identification system for Enterobacteriaceae was compared to the API 20E overnight method, using 230 fresh clinical isolates and 74 stock cultures. Agreement was 97.8% for the clinical isolates and 93.2% for the stock cultures. Eighty-seven percent of primary culture plates containing gram-negative rods yielded sufficient growth to perform the 4-h Micro-ID identification on the...
متن کاملTime-motion and cost comparison study of micro-ID, API 20E, and conventional biochemical testing in identification of Enterobacteriaceae.
A total of 730 Enterobacteriaceae strains isolated from 567 cultures were evaluated by a rapid kit method (Micro-ID; General Diagnostics, Morris Plains, N.J.; 4 h), an overnight incubation kit method (API 20E; Analytab Products, Plainview, N.Y.), and conventional biochemical test methodology (mostly overnight incubation and some rapid methods) to compare the amount of laboratory effort required...
متن کاملEvaluation and comparison of Hela, Hep2C and Vero cell lines sensitivity to polio vaccinal virus using micro and macro vaccine potency tests
Poliomyelitis, an acute viral infectious disease caused by poliovirus, still remains a public health problem in developing countries. Despite the global effort to eradicate polio, continuing the polio immunization with a potent and safe vaccine is essential. For accurate vaccine evaluation, three types of cell lines including Hela, Hep2C and Vero were evaluated and compared using two methods of...
متن کاملApplication of SSR Markers for Genetic Segregation of Some Commercial Date Palm Cultivars
Cultivar identification in micro-propagated date palm seedlings is laborious so that application of molecular markers to facilitate and acceleration of the procedure seems inevitable. Given the need for control the originality of micro- propagated date palm seedlings, the aim of this study was evaluation of SSR markers usability to cultivar identification in micro-propagated date palm seedlings...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 10 4 شماره
صفحات -
تاریخ انتشار 1979