Anodisation Increases Integration of Unloaded Titanium Implants in Sheep Mandible

نویسندگان

  • Warwick J. Duncan
  • Min-Ho Lee
  • Tae-Sung Bae
  • Sook-Jeong Lee
  • Jennifer Gay
  • Carolina Loch
چکیده

Spark discharge anodic oxidation forms porous TiO2 films on titanium implant surfaces. This increases surface roughness and concentration of calcium and phosphate ions and may enhance early osseointegration. To test this, forty 3.75 mm × 13 mm titanium implants (Megagen, Korea) were placed into healed mandibular postextraction ridges of 10 sheep. There were 10 implants per group: RBM surface (control), RBM + anodised, RBM + anodised + fluoride, and titanium alloy + anodised surface. Resonant frequency analysis (RFA) was measured in implant stability quotient (ISQ) at surgery and at sacrifice after 1-month unloaded healing. Mean bone-implant contact (% BIC) was measured in undemineralised ground sections for the best three consecutive threads. One of 40 implants showed evidence of failure. RFA differed between groups at surgery but not after 1 month. RFA values increased nonsignificantly for all implants after 1 month, except for controls. There was a marked difference in BIC after 1-month healing, with higher values for alloy implants, followed by anodised + fluoride and anodised implants. Anodisation increased early osseointegration of rough-surfaced implants by 50-80%. RFA testing lacked sufficient resolution to detect this improvement. Whether this gain in early bone-implant contact is clinically significant is the subject of future experiments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study

Reports have documented titanium (Ti) hypersensitivity after dental implant treatment. Alternative materials have been suggested including zirconia (Zr) ceramics, which have shown predictable osseointegration in animal studies and appear free of immune responses. The aim of the research was to investigate the bone-to-implant contact (BIC) of one-piece Zr, compared with one-piece Ti implants, pl...

متن کامل

The Effect Of Restoration Type On Osseointegration of Dental Implants: A Histological Analysis In Dogs

  Background and Objective: The concept of immediate occlusal loading with dental implants offers several advantages. In this research, the effect of type of restoration on Osseointegration rate of dental implants was histologically evaluated. Materials and Methods: Three months prior to implantation, the lower premolar teeth of 15 dogs were extracted. Then, 3 to 4 Maestro™ implants were plac...

متن کامل

Biologic width around titanium implants. A physiologically formed and stable dimension over time.

Research in implant dentistry has mainly focused on hard tissue integration with much less data available with regards to soft tissue integration involving epithelium and connective tissue. In the present study, the implantogingival junction of unloaded and loaded non-submerged titanium implants has been analyzed histometrically in the canine mandible. In 6 foxhounds, 69 implants were placed. D...

متن کامل

Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values.

PURPOSE The aim of this prospective case series study was to evaluate the short-term success rates of titanium screw-type implants with a chemically modified sand-blasted and acid-etched (mod SLA) surface after 3 weeks of healing. MATERIAL AND METHODS A total of 56 implants were inserted in the posterior mandible of 40 partially edentulous patients exhibiting bone densities of class I to III....

متن کامل

Comparison of zirconia and titanium implants after a short healing period. A pilot study in minipigs.

The aim of this animal study was to investigate and compare the osseointegration of zirconia and titanium dental implants. 14 one-piece zirconia implants and 7 titanium implants were inserted into the mandibles of 7 minipigs. The zirconia implants were alternately placed submerged and non-submerged. To enable submerged healing, the supraosseous part was removed, using a diamond saw. The titaniu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015