Evaluation of biplane color Doppler transesophageal echocardiography in 200 consecutive patients.

نویسندگان

  • R Omoto
  • S Kyo
  • M Matsumura
  • P M Shah
  • H Adachi
  • Y Yokote
  • Y Kondo
چکیده

BACKGROUND We developed the first biplane transesophageal echocardiography (TEE) probe with two orthogonal transducers, allowing synchronous side-by-side displays of the heart on a monitor TV, and compared its diagnostic value with that of conventional single-plane TEE using commercially available Doppler equipment in 200 consecutive patients intraoperatively, perioperatively, or on an outpatient basis. METHODS AND RESULTS Insertion was easy, except in one patient with a mediastinal tumor, and no complications were encountered. Both transverse and longitudinal scans allowed correct identification of true and false lumina in all 30 aortic dissection examinations, but longitudinal scanning was slightly superior in detecting types I and III entry sites. Three entries that were not detected by transverse scanning (two of DeBakey type I and one of type III) were visualized by longitudinal scanning. Among 37 cases of mitral regurgitation (MR), longitudinal scans were significantly superior (p less than 0.05) in revealing multiple jets (nine compared with two with transverse scanning). Although both planes yielded almost identical mean values for the maximum jet areas, a difference of over 50% in jet area size on the two planes was observed in 19 cases. The measured jet areas showed significant correlation with the angiographic MR grading, especially for the larger of the biplane measurements (p less than 0.01), and different grades showed little overlap. Longitudinal images increased the acoustic window of the heart and aorta from the esophagus. Moreover, longitudinal scanning provided good visualization of both ventricular outflow tracts, the ascending aorta, main pulmonary artery, and superior vena cava. CONCLUSIONS This modality greatly facilitates a three-dimensional comprehension of cardiovascular lesions and flow dynamics, especially in aortic dissection and MR, and its safety was demonstrated. Our data demonstrate the usefulness of this new technique in comparison with conventional single-plane TEE.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of left main coronary artery stenosis by transesophageal color Doppler and two-dimensional echocardiography.

Although transthoracic two-dimensional echocardiography can detect dilation of the coronary arteries, the reliability of this technique in the detection of coronary artery stenosis is still doubtful. The purpose of this study was to test the ability of newly developed biplane transesophageal color Doppler and two-dimensional echocardiography in the detection of left main coronary artery stenosi...

متن کامل

Intraoperative validation of mitral inflow determination by transesophageal echocardiography: comparison of single-plane, biplane and thermodilution techniques.

OBJECTIVES This study investigated the accuracy of mitral inflow quantification using biplane transesophageal echocardiography. BACKGROUND Mitral stroke volume can be reliably quantified by transthoracic Doppler echocardiography, but previous studies involving monoplane transesophageal echocardiography have yielded mixed results. METHODS Thirty patients without mitral regurgitation were pro...

متن کامل

Quantification of left-to-right atrial shunting and defect size after balloon mitral commissurotomy using biplane transesophageal echocardiography, color flow Doppler mapping, and the principle of proximal flow convergence.

BACKGROUND The flow convergence region (FCR), a zone of progressive laminar velocity acceleration, can be imaged by color Doppler proximal to stenotic and regurgitant orifices. Theoretically, FCR proximal to a discrete circular and planar orifice consists of concentric hemispheric shells of equal and accelerating velocities centered at the orifice. According to the continuity principle, flow ra...

متن کامل

Rapid diagnosis and management of thoracic aortic dissection and intramural haematoma: a prospective study of advantages of multiplane vs. biplane transoesophageal echocardiography.

AIMS The purposes of this study were to compare the accuracy of multiplane vs. biplane transoesophageal echocardiography (TEE) in the diagnosis of aortic dissection and aortic intramural haematoma, and to test whether these techniques provide all the diagnostic information required to make management decisions. METHODS AND RESULTS Fifty-eight consecutive patients with clinically suspected aor...

متن کامل

Transesophageal Echocardiography in 200 Consecutive Patients

Background. We developed the first biplane transesophageal echocardiography (TEE) probe with two orthogonal transducers, allowing synchronous side-by-side displays of the heart on a monitor TV, and compared its diagnostic value with that of conventional single-plane TEE using commercially available Doppler equipment in 200 consecutive patients intraoperatively, perioperatively, or on an outpati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 85 4  شماره 

صفحات  -

تاریخ انتشار 1992