A focused ultrasound treatment system for moving targets (part I): generic system design and in-silico first-stage evaluation

نویسندگان

  • Michael Schwenke
  • Jan Strehlow
  • Daniel Demedts
  • Sabrina Haase
  • Diego Barrios Romero
  • Sven Rothlübbers
  • Caroline von Dresky
  • Stephan Zidowitz
  • Joachim Georgii
  • Senay Mihcin
  • Mario Bezzi
  • Christine Tanner
  • Giora Sat
  • Yoav Levy
  • Jürgen Jenne
  • Matthias Günther
  • Andreas Melzer
  • Tobias Preusser
چکیده

BACKGROUND Focused ultrasound (FUS) is entering clinical routine as a treatment option. Currently, no clinically available FUS treatment system features automated respiratory motion compensation. The required quality standards make developing such a system challenging. METHODS A novel FUS treatment system with motion compensation is described, developed with the goal of clinical use. The system comprises a clinically available MR device and FUS transducer system. The controller is very generic and could use any suitable MR or FUS device. MR image sequences (echo planar imaging) are acquired for both motion observation and thermometry. Based on anatomical feature tracking, motion predictions are estimated to compensate for processing delays. FUS control parameters are computed repeatedly and sent to the hardware to steer the focus to the (estimated) target position. All involved calculations produce individually known errors, yet their impact on therapy outcome is unclear. This is solved by defining an intuitive quality measure that compares the achieved temperature to the static scenario, resulting in an overall efficiency with respect to temperature rise. To allow for extensive testing of the system over wide ranges of parameters and algorithmic choices, we replace the actual MR and FUS devices by a virtual system. It emulates the hardware and, using numerical simulations of FUS during motion, predicts the local temperature rise in the tissue resulting from the controls it receives. RESULTS With a clinically available monitoring image rate of 6.67 Hz and 20 FUS control updates per second, normal respiratory motion is estimated to be compensable with an estimated efficiency of 80%. This reduces to about 70% for motion scaled by 1.5. Extensive testing (6347 simulated sonications) over wide ranges of parameters shows that the main source of error is the temporal motion prediction. A history-based motion prediction method performs better than a simple linear extrapolator. CONCLUSIONS The estimated efficiency of the new treatment system is already suited for clinical applications. The simulation-based in-silico testing as a first-stage validation reduces the efforts of real-world testing. Due to the extensible modular design, the described approach might lead to faster translations from research to clinical practice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strategy-aligned fuzzy approach for market segment evaluation and selection: a modular decision support system by dynamic network process (DNP)

In competitive markets, market segmentation is a critical point of business, and it can be used as a generic strategy. In each segment, strategies lead companies to their targets; thus, segment selection and the application of the appropriate strategies over time are very important to achieve successful business. This paper aims to model a strategy-aligned fuzzy approach to market segment ev...

متن کامل

Development, and evaluation of drug monitoring system for multiple sclerosis patients

Background and Aim: Taking a wide range of medications in Multiple sclerosis (MS) patients can lead to side effects and drug interactions. Therefore, the use of intelligent systems such as drug monitoring systems can help in the effective and timely treatment of MS disease. In this regard, the present study was conducted to design, development, and evaluation of the drug monitoring system for m...

متن کامل

In-silico Metabolome Target Analysis Towards PanC-based Antimycobacterial Agent Discovery

Mycobacterium tuberculosis, the main cause of tuberculosis (TB), has still remained a global health crisis especially in developing countries. Tuberculosis treatment is a laborious and lengthy process with high risk of non compliance, cytotoxicity adverse events and drug resistance in patient. Recently, there has been an alarming rise of drug resistant in TB. In this regard, it is an unmet need...

متن کامل

Design and Production of a Pneumatic Moving Exciter for Determination of Vibration Behavior of Structures in Variable Frequencies

Determination and analysis of vibration behavior of structures for at least first few natural frequencies and mode shapes needs several sensors to be connected at different non node points and exciting the structure at one point. Other method for determination of first few mode shapes is to excite several points of the structure at once and sensing the response from one point.  Both methods nee...

متن کامل

In-silico Metabolome Target Analysis Towards PanC-based Antimycobacterial Agent Discovery

Mycobacterium tuberculosis, the main cause of tuberculosis (TB), has still remained a global health crisis especially in developing countries. Tuberculosis treatment is a laborious and lengthy process with high risk of non compliance, cytotoxicity adverse events and drug resistance in patient. Recently, there has been an alarming rise of drug resistant in TB. In this regard, it is an unmet need...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017