Variation associated with measurement of retinal vessel diameters at different points in the pulse cycle.

نویسندگان

  • M D Knudtson
  • B E K Klein
  • R Klein
  • T Y Wong
  • L D Hubbard
  • K E Lee
  • S M Meuer
  • C P Bulla
چکیده

BACKGROUND/AIMS To assess the variability in retinal vessel measurements at different points in the pulse cycle. METHODS A healthy white male aged 19 years had 30 digitised images taken at three distinct points in the pulse cycle over a one hour period. A pulse synchronised ear clip trigger device was used to capture images at the desired point in the pulse cycle. Two trained graders measured the retinal vessel diameter of one large arteriole, one large venule, one small arteriole, and one small venule 10 times in each of these 30 images. RESULTS Within an image, variability was similar between graders, pulse point, and vessel type. Across images taken at the same point in the pulse period, the change from the minimum to maximum measurement was between 6% and 17% for arterioles and between 2% and 11% for venules. In addition, measurements of small vessels had greater changes than large vessels and no point in the pulse period was more variable than another. Ignoring pulse cycle increased variability across images in the large venule, but not in the other vessel types. Mixed effect models were fit for each of the vessel types to determine the greatest source of variability. Controlling for pulse point and grader, the largest source of variability for all four vessels measured was across images, accounting for more than 50% of the total variability. CONCLUSION Measurements of large retinal venules is generally less variable than measurements of other retinal vessels. After controlling for pulse point and grader, the largest source of variation is across images. Understanding the components of variability in measuring retinal vessels is important as these techniques are applied in epidemiological studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extracting Vessel Centerlines From Retinal Images Using Topographical Properties and Directional Filters

In this paper we consider the problem of blood vessel segmentation in retinal images. After enhancing the retinal image we use green channel of images for segmentation as it provides better discrimination between vessels and background. We consider the negative of retinal green channel image as a topographical surface and extract ridge points on this surface. The points with this property are l...

متن کامل

Direct measurement of retinal vessel diameter: comparison with microdensitometric methods based on fundus photographs.

A new method for the direct measurement of retinal vessel diameter was developed and the results were compared with those of two computer-assisted semiautomatic microdensitometric methods. The direct measurement method was based on automated detection of vessel edges by processing the one-dimensional retinal image obtained by a linear image sensor set in a fundus camera; results are obtained in...

متن کامل

Simulation study of Hemodynamic in Bifurcations for Cerebral Arteriovenous Malformation using Electrical Analogy

Background and Objective: Cerebral Arteriovenous Malformation (CAVM) hemodynamic is disease condition, results changes in the flow and pressure level in cerebral blood vessels. Measuring flow and pressure without catheter intervention along the vessel is big challenge due to vessel bifurcations/complex bifurcations in Arteriovenous Malformation patients. The vessel geometry in CAVM patients are...

متن کامل

Computer algorithms for the automated measurement of retinal arteriolar diameters.

AIMS Quantification of retinal vascular change is difficult and manual measurements of vascular features are slow and subject to observer bias. These problems may be overcome using computer algorithms. Three automated methods and a manual method for measurement of arteriolar diameters from digitised red-free retinal photographs were compared. METHODS 60 diameters (in pixels) measured by manua...

متن کامل

Effects of dopamine on human retinal vessel diameter and its modulation during flicker stimulation.

We performed a randomized, subject-blinded, placebo and time-controlled, two-way crossover study in 12 healthy male subjects. Placebo or dopamine was administered on two separate study days. After saline infusion, dopamine hydrochloride was infused in three consecutive doses (5, 10, and 15 microg x kg(-1) x min(-1)). Plasma levels of dopamine were determined at each perfusion step. Arterial and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 88 1  شماره 

صفحات  -

تاریخ انتشار 2004