The value of observer performance studies in dose optimization: a focus on free-response receiver operating characteristic methods.

نویسندگان

  • John D Thompson
  • David J Manning
  • Peter Hogg
چکیده

Receiver operating characteristic (ROC) analysis has been successfully used in radiology to help determine the combined success of system and observer. There is great value in these methods for assessing new and existing techniques to see if diagnostic accuracy can be improved. Within all aspects of radiology there should be compliance with the as-low-as-reasonably-achievable principle, which requires optimization of the diagnostic suitability of the image. Physical measures of image quality have long been used in the assessment of system performance, but these alone are not sufficient to assess diagnostic capability. It is imperative that the observer be included in any assessment of diagnostic performance. The free-response ROC paradigm has been developed as a statistically powerful advancement of traditional ROC analysis that allows a precise interpretation of complex images by adding location information to the level of observer confidence. The following review of free-response ROC methodology will explain how observer performance methods can be valuable in image optimization, including examples of how these have already been successful in hybrid imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of the free-response receiver operating characteristic method for dose and image quality optimisation

........................................................................................................................... viii Abbreviations and Definitions........................................................................................... ix Publications ....................................................................................................................... xi Prelimin...

متن کامل

Application of adjusted-receiver operating characteristic curve analysis in combination of biomarkers for early detection of gestational diabetes mellitus

Introduction: In medical diagnostic field, evaluation of diagnostic accuracy of biomarkers or tests has always been a matter of concern. In some situations, one biomarker alone may not be sufficiently sensitive and specific for prediction of a disease. However, combining multiple biomarkers may lead to better diagnostic.  The aim of this study was to assess the performance of combination of bio...

متن کامل

Effect of dose reduction on the detection of mammographic lesions: a mathematical observer model analysis.

The effect of reduction in dose levels normally used in mammographic screening procedures on the detection of breast lesions were analyzed. Four types of breast lesions were simulated and inserted into clinically-acquired digital mammograms. Dose reduction by 50% and 75% of the original clinically-relevant exposure levels were simulated by adding corresponding simulated noise into the original ...

متن کامل

Basic concepts and development of an all-purpose computer interface for ROC/FROC observer study.

In this study, we initially investigated various aspects of requirements for a computer interface employed in receiver operating characteristic (ROC) and free-response ROC (FROC) observer studies which involve digital images and ratings obtained by observers (radiologists). Secondly, by taking into account these aspects, an all-purpose computer interface utilized for these observer performance ...

متن کامل

Receiver Operating Characteristic (ROC) Curve Analysis for Medical Diagnostic Test Evaluation

This review provides the basic principle and rational for ROC analysis of rating and continuous diagnostic test results versus a gold standard. Derived indexes of accuracy, in particular area under the curve (AUC) has a meaningful interpretation for disease classification from healthy subjects. The methods of estimate of AUC and its testing in single diagnostic test and also comparative studies...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2013