We report a case of right heart failure (RHF) and sepsis with liver insufficiency in a 70-year-old patient after coronary artery bypass graft surgery. Three hours after surgery the patient suddenly developed therapy refractory cardiac arrest caused by RHF. He had to have emergency surgery, under which the graft to the right coronary artery was revised and a right ventricular assist device was implanted. Heart function recovered and the assist device was explanted on day 1 after surgery. Thoracic closure was performed on day 5 after surgery. The patient went into septic shock on day 11. Liver dysfunction developed postoperatively and worsened the course of sepsis. Therefore, MARS (molecular adsorbents recirculating system) dialysis was performed once on day 20 after surgery. Liver function improved after MARS therapy and the patient recovered from sepsis. On day 46 the patient was transferred from the ICU of another hospital to one of the peripheral wards, to be finally discharged on day 67.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Main indications and long-term outcomes of reoperation after initial repair of tetralogy of Fallot

Background and Objective: The aim of this study was to analyze our indications, surgical procedures, and clinical outcomes of patients undergoing reoperation after surgical correction of tetralogy of Fallot (TOF). Methods: Thirty seven consecutive patients who underwent reoperation late after intra-cardiac repair of TOF within a period of 10 years were assessed. Results: The most co...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Hemolysis and Pulmonary Insufficiency following Right Ventricular Assist Device Implantation

We report a case of severe hemolysis and pulmonary valve insufficiency (PI) following right ventricular support using a paracorporeal pneumatic pump (Abiomed, Danvers, MA, USA). We speculate that the high velocity jet of blood emanating from the outflow cannula caused turbulence above the pulmonary valve, leading to PI and hemolysis. Despite the growing number of implanted ventricular assist de...

متن کامل

A novel use of the implantable ventricular assist device for isolated right heart failure.

Isolated right heart failure after cardiac surgery is uncommon and the prognosis remains poor. Additionally, managements for these patients are difficult. Profound postcardiotomy right heart failure developed in a 45-year-old woman after aortic root replacement for critical aortic stenosis with small aortic root. Although maximum medical therapy, intraaortic balloon counterpulsation and extraco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Artificial organs

دوره 28 8  شماره 

صفحات  -

تاریخ انتشار 2004