The Comparison of Central and Mean True-Net Power (Pentacam) in Calculating IOL-Power After Refractive Surgery

نویسندگان

  • Jeong-Ho Yi
  • Joo Youn Shin
  • Byoung Jin Ha
  • Sang Woo Kim
  • Beom Jin Cho
  • Eung Kweon Kim
  • Tae-im Kim
چکیده

PURPOSE To compare the accuracy of central true net corneal power (cTNP) and mean true net corneal power (mTNP) of the Pentacam system to give a keratometry (K) reading for calculating IOL (intraocular lens) power in eyes following refractive surgery. METHODS Refraction, an automated K-reading (Km), cTNP and mTNP were measured for 15 eyes that required cataract surgery and had previously undergone refractive surgery. The difference between postoperative manifest refraction values and target refraction values calculated with the SRK/T formula using cTNP were compared with the one using mTNP. RESULTS The mean deviation from the desired post-cataract refractive outcome was 0.60 diopter (D)+/-0.47 (standard deviation) using cTNP; 0.75+/-0.54 using mTNP (p=0.386). The actual refraction was within +/-0.50D of the intended refraction for 60% (cTNP) and 33.3% (mTNP) of eyes, and within +/-1.00D for 93% (cTNP) and 66.7% (mTNP) of eyes. CONCLUSIONS Although not statistically significant, the cTNP showed better accuracy than mTNP to give a keratometry (K) reading for post-refractive surgery eyes requiring cataract surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pentacam keratometric values unreliable for IOL power calculation after refractive surgery.

Pentacam Keratometric Values Unreliable for IOL Power Calculation After Refractive Surgery To the Editor: We read with interest the article by Gonen et al,1 which appeared in the August 2012 issue of the Journal of Refractive Surgery, on their study comparing keratometric data from 200 patients evaluated for refractive surgery using four different devices—an automated keratometer (KR 8800 [Topc...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery.

PURPOSE To determine the accuracy of Pentacam Scheimpflug system Holladay equivalent keratometry (K) readings (EKRs) in calculating intraocular lens (IOL) power after corneal refractive surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and radial keratotomy (RK). SETTING Jules Stein Eye Institute, David Geffen School of Medicine at University of Calif...

متن کامل

Corneal power measurements using scheimpflug imaging in eyes with prior corneal refractive surgery.

PURPOSE To evaluate the accuracy of central corneal power measurements by Scheimpflug imaging (Pentacam) for eyes that had corneal refractive surgery. METHODS This study comprised two groups: a pilot group of 100 eyes with prior hyperopic or myopic LASIK that did not have cataract surgery, and a test group of 41 eyes with prior radial keratotomy (RK) and cataract surgery. In the pilot group, ...

متن کامل

Comparison of astigmatism prediction error taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens implantation

BACKGROUND To evaluate and compare the astigmatism prediction errors taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens (IOL) implantation. METHODS Phacoemulsification with toric Precizon IOL implantation was performed in 41 eyes with corneal astigmatism (range, 1 to 5 diopters (D)) determined by IOLMaster and SimK on Pentacam. Preoperative c...

متن کامل